 MAINTE

NANCE

 

For the first t

w

o w

eeks of use

, y

ou should not shake the dust c

ollec

tor

’s bags

. T

his will 

allo

w the dust t

o cr

ea

te a thin la

yer on the inside of the bag

, incr

easing the filt

er

ing 

efficienc

y. I

t also e

xplains wh

y new bags ma

y leak f

or the first hours of use

.

 

E

VE

R

Y 2,000 HOURS OF OPE

RA

TION

D

AIL

Y MAINTE

NANCE

 & OPE

RA

TION

Replac

e bags          

 

when the dust c

ollec

tor is unable t

o ev

acua

te the dust cloud

 

fr

om the cabinet or af

ter 

ev

er

2,000 hours of oper

ation.

3.

 

A

ft

er each use

, tur

n off the impeller and shake bags inside the dust c

ollec

tor

Nev

er shake bags while the cabinet is running

.

4.

 

Empt

y optional dust bar

rel or dust c

ollec

tor

’s bott

om hopper r

egular

ly

.  

N

ev

er shak

e bags while the c

abinet is r

unning

. N

ev

er w

ash bags

, inst

ead use

 

compr

essed 

 use 

compr

essed 

air

, blo

wing 

fr

om 

the 

outside 

to 

the 

inside 

of 

the 

bag

(the opp

osit

e w

ould clo

g the bag

’s p

or

es and mak

e it unusable).

Bag shack

ing should ne

ver o

ccur while the elec

tric mot

or is r

unning

.  

A

lw

ay

s w

ait f

or c

omplet

e st

op of elec

tric mot

or t

o a

void t

earing off bags

 #

ST

OCK

DESCRIPTION

3

601316

          

DB-

6 B

AGHOUSE

1.   I

f y

our dust c

ollec

tor is equipped with the aut

oma

tic shacker option, the ac

tion will 

oc

cur aut

oma

tically a

t mot

or

’s shut do

wn

2.

 

Remo

ve 

dust 

fr

om 

the 

dust 

collec

tor 

on 

regular 

basis

. B

ef

or

opening 

the 

door

make sur

e t

o ha

ve a c

on

tainer under the tr

ap t

o c

ollec

t the dust

(pic

tur

e 1)

 

If y

ou ar

e equipped with the dust drum option simply open the lid with the 

ring

’s lev

er 

(pic

tur

e 2

) and empt

y dust

.

Pic

tur

e 1

Pic

tur

e 2

1

3

2

3

Summary of Contents for DC100

Page 1: ...AL 2022 04 05 International Surface Technologies istsurface com A leader in surface treatment Warranty Safety Operation Service Parts Accessory Information Registration Form BAGHOUSE DUST COLLECTORS DCM100 TO 330 120 V ...

Page 2: ...SE DUST COLLECTORS DCM100 TO 330 1 INTRODUCTION 3 NOTICE TO PURCHASERS 4 GENERAL SAFETY RULES UNIT USE AND CARE 5 INSTALLATION 6 7 BAGHOUSE DUST COLLECTOR PARTS LIST CHARTS 8 9 ELECTRICAL SHACKER OPTIONAL INSTALLATION 10 MAINTENANCE 11 ELECTRICAL SCHEMATICS 12 TO 16 ISTBLAST LIMITED WARRANTY 17 INFORMATION TECHNICAL ASSISTANCE 18 OUR MAP LOCATION 19 ABOUT THE COMPANY 20 ...

Page 3: ...often indicates possibility of transport damage to the equipment inside 2 Carefully remove your ISTblast dust collector from the shipping carton and skid 3 Check your equipment immediately to ensure that it is free of transport damage Report any transport damage to the carrier without delay for possible claim procedures ISTblast is not responsible for damage to equipment after it leaves our wareho...

Page 4: ... ways for purposes determined solely by the user No representations are intended or made as to the suitability or engineering balance of the combination of products determined by the user in his selection nor as to the compliance with regulations or standard practice of such combinations of components or products Itistheresponsibilityoftheknowledgeable experiencedusersoftheproductsmentionedinthism...

Page 5: ...alance at all times BEFORE STARTING TO WORK you must wear earing protections efficient for 80 dB or more UNIT USE AND CARE DO NOT FORCE THE UNIT It will perform better and safer at the rate for which it was designed THE USE OF ANY OTHER ACCESSORIES not specified in this manual may create a hazard CLOSE THE MAIN BREAKER SWITCH BEFORE SERVICING or when not in use DO NOT ALTER OR MISUSE THE UNIT Thes...

Page 6: ...here the turbine can be readily observed The right direction of rotation is indicated by an arrow The impeller should rotate toward the blower If the rotation is not the same please notify an electrician so that it performs the necessary change INSTALLATION GROUNDING To prevent static electricity from accumulation connect the ground wire of the dust collector to a connection anchored to the factor...

Page 7: ...he adapter To ensure right air circulation it is essential to keep 18 inches of clearance in front of the air outlet of the muffler See details in section MUFFLER INSTALLATION on pages 8 9 11 Connect your shop s air supply line to the dust collector air inlet Your air supply is coupled to the air inlet with a inch male quick connect coupling 6A see details page 8 To properly operate your IST syste...

Page 8: ...gulator 6A Air inlet M quick connect 607222 F 607219 7 608406 Hinge axle 8 608405 Cylinder 9 608407 Hinge plate 10 610280 Adjustable air trap STOCK DESCRIPTION 11 610287 Door handle 12 610223 Toggle lock 13 910223 Toggle stem 14 601378 Trap door for dust 15 618321 D type rubber sold per foot 16 616575 Electric cable sold per foot 17 616406 Electrical plug 18 617063 Electrical box 19 601309 S Hook ...

Page 9: ...0 601436 601425 DCM 330 601490 30 601437 601426 21 22 23 FAN MOTOR Fan Motor hp Motor voltages Impeller 240 V 380 V 1 2 IST N A 610525 1 IST N A 610526 2 IST N A 610527 3 N A IST 610528 5 N A IST 610529 7 5 N A IST IST 10 N A IST IST FAN MOTOR SUCTION HOSE 1 1 2 2 3 CORRUGATED SUCTION HOSES AND CLAMPS Fan Motor hp Hose ID Hose Clamp 1 2 5 606168 624121 1 6 606169 624124 2 7 606171 624127 3 8 60617...

Page 10: ...rface com 10 DCM100 to 330 Dust Collector Instruction Manual Parts ELECTRICAL SHACKER OPTIONAL STOCK DESCRIPTION 1 917850 TIMERS 2 324560 PUSHIN FITTINGS 3 608568 SOLENOID VALVE 4 608284 MUFFLER 5 608405 PNEUMATIC CYLINDER 1 3 2 4 5 For electrical schematic see pages 12 to 15 ...

Page 11: ...ide the dust collector Never shake bags while the cabinet is running 4 Empty optional dust barrel or dust collector s bottom hopper regularly Never shake bags while the cabinet is running Never wash bags instead use compressed use compressed air blowing from the outside to the inside of the bag the opposite would clog the bag s pores and make it unusable Bag shacking should never occur while the e...

Page 12: ...national Surface Technologies istsurface com 12 DCM100 to 330 Dust Collector Instruction Manual Parts ELECTRICAL SCHEMATIC FOR DCM 50 TO 330 BAG TYPE 120 V 1 PH DIAGRAM CUSTOMER SUPPLY DCM100 TO 330 1 Ph 120 V POWER CONTROL 1 5 1 877 629 8202 ...

Page 13: ...nologies istsurface com 13 DCM100 to 330 Dust Collector Instruction Manual Parts ELECTRICAL SCHEMATIC FOR DCM 100 TO 330 BAG TYPE 120 V 1 PH PARTS LIST 15 A 120 V MALE PLUG WITH POWER CORD SOLENOID Supplier DCM 100 TO 330 120 V 1 Ph PARTS LIST 1 877 629 8202 2 5 ...

Page 14: ...eatment International Surface Technologies istsurface com 14 DCM100 to 330 Dust Collector Instruction Manual Parts ELECTRICAL SCHEMATIC FOR DCM 100 TO 330 BAG TYPE 3 PH DIAGRAM 3 4 1 877 629 8202 DCM 100 TO 330 3 Ph POWER CONTROL ...

Page 15: ...ent International Surface Technologies istsurface com 15 DCM100 to 330 Dust Collector Instruction Manual Parts ELECTRICAL SCHEMATIC FOR DCM 100 TO 330 BAG TYPE 3 PH PARTS LIST Supplier 4 5 1 877 629 8202 DCM100 TO 330 3 Ph PARTS LIST ...

Page 16: ...ace treatment International Surface Technologies istsurface com 16 DCM100 to 330 Dust Collector Instruction Manual Parts REFERENCE LIST FOR FOR DCM 50 TO 330 BAG TYPE 3 PH 5 5 DCM100 À 330 3 Ph REFERENCE LIST 1 877 629 8202 ...

Page 17: ...ion of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ISTblast s sole o...

Page 18: ...rts INFORMATION TECHNICAL ASSISTANCE www istsurface com TEL 1 877 629 8202 450 963 4400 FAX 450 963 5122 For more information pricing or technical support contact your local IST distributor or call fax to our Consumer Information numbers Or visit us at International Surface Technologies istsurface com ISTpure is a registered trademark of ...

Page 19: ...The reference in surface treatment International Surface Technologies istsurface com 19 DCM100 to 330 Dust Collector Instruction Manual Parts OUR MAP LOCATION ...

Page 20: ...uipment for the surface treatment industry and the solvent recycling industry MISSION IST is dedicated to being an innovative and trusted supplier in the conception fabrication and distribution of surface treatment equipment and recycling equipment The success of our mission relies on the following core values Innovation Integrity Quality The products technologies and industry expertise of IST are...

Reviews: