DCM100 to 330 Dust Collector - Instruction Manual & Parts
1. The dust collector should be located on a leveled area near the back of the cabinet, while respecting
the laws and regulations in your area. Allow access to components such as the pressure gauge, fan,
door and hatch, the barrel, the cartridges and cleaning system.
2. Make sure the equipment is leveled, installed on a solid surface, and well grounded. Do not place
on a wooden floor or a rubber mat, unless a ground wire has been installed. Check with a qualified
electrician.
3. This dust collector requires an electrical connection. The electrical connections depend on the size
and number of motor phases. Refer to the Electrical drawings on pages 12 to 16.
4. After the installation is complete, verify the direction of rotation of the turbine. To check the
direction of rotation, turn on and turn off the engine quickly to provoke a slow rotation of the
blades. Look inside the slots above the engine where the turbine can be readily observed. The
right direction of rotation is indicated by an arrow. The impeller should rotate toward the blower.
If the rotation is not the same, please notify an electrician so that it performs the necessary change
INSTALLATION
GROUNDING:
To prevent static electricity from accumulation, connect the ground wire of the
dust collector to a connection anchored to the factory ground.
5. Check the amperage on initial startup. If the engine uses too much amperage, gradually close the wall until
the data meets the specified amperage of the motor plate. The partition is located at the fan outlet.
ALL ELECTRICAL CONNECTIONS TO THE ISTBLAST EQUIPMENT SHOULD BE MADE BY A QUALIFIED ELECTRICIAN AND MUST
ADHERE TO THE CODES, STANDARDS, AND PROCEDURES SPECIFIED BY THE AUTHORITY HAVING JURISDICTION.
THE CUSTOMER IS RESPONSIBLE FOR PROVIDING APPROPRIATE DISCONNECTING MEANS ADJACENT TO THE
EQUIPMENT FOR EACH INCOMING POWER CIRCUIT.
BEFORE PROCEEDING TO INSTALLATION, THE ELECTRIC POWER SUPPLY MUST BE LOCKED AND TAGGED. FAILURE TO COMPLY
WITH THIS COULD RESULT IN SERIOUS INJURIES DUE TO ELECTRIC SHOCK.
.
NEVER LOOK INSIDE THE EXIT OF THE FAN WHEN THE FAN IS RUNNING. FAN EJECTED DEBRIS COULD CAUSE INJURY.
CAUTION
CAUTION