background image

 

 

14 

pressure, the three-phase dump load will stop discharging to 

automatically recover battery charging. Then the image not 

displayed.

 

 

 

LCD display in digital form 

show 

the parameters value.

 

Fuse burn 

Fuse  burn  indicator  light,  when  fuse burn,  remind  users 

replace the fuse

Polarity Reverse 

Polarity  Reverse indicator  light,  when  the  battery  polarity 

reversed. Remind users properly connected to the battery. 

 

3. 

LCD display parameters browse

 

1

After plus electric

, s

ystem is in viewing conditions, LCD display battery voltage: 

Battery XXX.XV.

 

2

 

In viewing conditions

,

 

press the front button of the case, will according to the 

following order cyclic display parameters

.

 

Battery  voltage 

 

charge  current

 

 

charge  power 

 

Wind  turbine 

v

oltage

 

 

Wind  turbine  charge  current 

 

Wind  turbine  power 

  Solar  panel  voltage 

 

Solar panel charge current 

  Solar panel power 

  Battery voltage

.

 

ϱϨ

 Attentions 

We have taken full consideration of possibilities of occurring all kinds of accidents in 

design  of  the  machine  and  adopted  relative  protective  measures.  But  there  is  no 

perfect  protective  measure.  Frequent  use  of  some  functions  (e.g.:  short-circuit 

protection,  battery  reverse  connection  protection)  can  cause  great  damage  to  the 

internal  components  of  the  machine.  So,  users  shall  not  depend  on  these  protective 

measures. The following attentions are very important for prolonging the service life 

of the machine: 

1.

 

Failures  can  be  caused  by  many  main  reasons,  among  which  are  exhaustion  of 

battery or battery group and poor contact.

 

●In the  charging process, exhausted battery  or  poor  contact of  the  battery  can 

cause  over  voltage  or  low  voltage;  Frequent  unload  and  braking  can  lead  to 

Summary of Contents for FKJ-B(PWM)-1KW48Vdc

Page 1: ...Model FKJ B PWM 1KW48V With 600W Solar PWM WIND SOLAR HYBRID CHARGE CONTROLLER USER MANUAL Read the user manual carefully before use...

Page 2: ...roller 6 Usage 6 Operation Steps 7 Remove wiring step controller 8 Failure Analysis 11 Box diagram 11 Liquid crystal screen operation and display 12 Attentions 14 Maintenance of Battery 15 Functional...

Page 3: ...that electrician make a install Using direction make sure read this instruction book carefully before appliance The equipment must be installed by professionals To avoid personal injury make sure it...

Page 4: ...duct for many times by the state in the assistance project of exported wind energy PWM model Product Characteristics The product is manufactured according the JB T6939 1 2004 industrial standard and G...

Page 5: ...5 of the rated voltage the controller will carry out three phase dump load automatically to stop charging the battery Auto recharging of battery When the battery voltage reduces to 108 of the rated vo...

Page 6: ...connect the solar panels with the solar of the controller Connect the PWM dump load terminal on the unloader with the PWM dump load terminal on the controller connect them in accordance with the wiri...

Page 7: ...on the back plate on RUM the wind turbine is in operation state 2 When the machine is not in use or the wind is too strong or in dismantlement of the battery loof the wind turbine then place the switc...

Page 8: ...tilated Operating environment which is under direct sunlight exposed to sunshine humid and full of acid mist is forbidden Operating environment which has dust and dirt is forbidden Put the machine in...

Page 9: ...9 Remove wiring step controller...

Page 10: ...10...

Page 11: ...rbine shall be turn off immediately to check whether the fuse is blown the battery is connected well or the battery is damaged 2 After the battery is connected but the wind turbine can not work and th...

Page 12: ...y 1 Operation explanation Press the front panel of the button LCD screen light Each press parameters change again Stop the operation 1 minute LCD screen automatically put out to save electricity 2 Dis...

Page 13: ...s to charge the battery When the battery voltage is too low the frame of the battery image will flashing remind users battery is low voltage at this time please stop using battery to charge battery un...

Page 14: ...e Wind turbine charge current Wind turbine power Solar panel voltage Solar panel charge current Solar panel power Battery voltage Attentions We have taken full consideration of possibilities of occurr...

Page 15: ...rge the battery separately 2 The maintenance free battery shall be maintained periodically in accordance with user manual of the maintenance free battery 3 Misconnection of the electrode of the batter...

Page 16: ...rtition board reveal on it 8 The electrolyte shall be adjusted to normal density 1 26 1 28 g cm3 this parameter may be based upon the user manual and this can only be done after battery charging is en...

Page 17: ...17 Functional Diagram Wiring diagram PWM off grid Controller Unloader...

Page 18: ...panel voltage solar panel current solar panel power battery voltage charge current PWM constant pressure voltage 58Vdc 3 phase brake voltage of the wind turbine 60 1Vdc Recovery charging voltage of t...

Page 19: ...320 Weight of the controller 18 Kg Size of the dump load mm 480 360 200 Weight of the dump load 6 5 Kg Warning Dismantlement of the unloader in the use is forbidden The unloader must be connected in...

Reviews: