15
damage of the controller.
●It is suggested that the capacity of the battery be checked periodically (with
specific measuring tools instead of universal meter). Each and every battery shall
go through checks of the capacity, contact condition and timely erasing of rust on
the terminals of positive and negative electrodes. (The checks shall be done
when the wind turbine is in brake state.)
●
The battery voltage drop to less than 85% rated voltage,
the frame of
the battery image will flashing, remind users battery is low voltage, at this time,
should stop used immediately,
timely to charge battery. Otherwise, battery will
damaged.
●This machine can not charge the exhausted or damaged battery. When voltage
of the battery is 75% lower than the rated voltage, replace the battery in time or
charge the battery separately.
2. The maintenance-free battery shall be maintained periodically in accordance with
user manual of the maintenance-free battery.
3. Misconnection of the electrode of the battery is forbidden.
4. Owing to the unloader equipped on this machine can produce high temperature
in working , please put it in the place with better ventilation and heat dispersion
and 2 meters away from the host and where the man or livestock can not reach.
Covering with other objects or using it under the flammable or explosive gas
environment is forbidden to prevent fire.
5. The machine should be managed by professionals for your safety. It should be
grounded reliably to resist electric shock. The ground resistance should be less
than 1Ω and the connecting wire should be larger than 10
²mm.
ϱϩ
Maintenance of Battery
Maintenance of battery is a key link in work. Different maintenance methods are
used to different kinds of batteries or battery series. For the lead-acid battery (except