(4)
Press and hold "MENU" for 3 seconds to enter the following user menu settings:
TIME OF DAY, YEAR, MONTH, DAY:
Time of day is for normal operation and the scheduling of the
regeneration time. The date is used in adiagnostic function to
track the last time the system regenerated.
SET HARDNESS:
This value is the maximum compensated water hardness of the
raw water supply in grains per gallon. It isused to calculate the
system capacity. If Ferrous Ironis present, add 4 gpG for every
1 ppm of Ferrous Iron.
SET PEOPLE:
This value is the number of people living in the home. It is used
to calculate the amount of water needed for daily use and the
reserve capacity of the system.
SALT SETTING:
There are 3 settings to choose in the MENU SETTINGS. High
Efficiency, Standard Capacity, and IRON& MN. These settings
will determine the salt dosage and capacity for the system.
WATER SOURCE:
This setting will determine if the BACKWASH OVERRIDE
function will be on or off. Select MUNICIPAL if the water source
is clean (<1NTU turbidity) and the system will skip the
backwash cycle based on the setting in BACKWASH
OVERRIDE.
Select WELL / OTHER if any Iron or Manganese is present or if
the water source is not clean (>1NUT turbidity). The system will
back wash every time.
REGEN TIME:
Determines the time of day to perform a scheduled
regeneration. You can set the system's regeneration time
according to your routine or schedule. It is recommended to set
it in a period when water is not in use. The system defaults to
02:00 a.m.
LOAD DEFAULT:
If the selection is made, the processing time of each
regeneration cycle will be reset to the default value setting. The
rinse time will return to the default value.