background image

-10- 

Main part 

of faucet

Stainless steel 

faucet

Inlet water 

connection

                             

 

Diagram 7                                                                                  Diagram 8

 

 Wastewater pipe installation 

Using a drill, make a φ6.2mm hole into the sink pipe drain. Take out an appropriate length of the 6mm pipe.   
One end should be inserted into the small hole (see diagram 8).    Put some silica gel where the 6mm pipe 

and  the  drain  pipe  connect  to  prevent  leakage.    Then,  using  a  cable  tie,  fix  the  wastewater  pipe  to  the 

drain pipe. 

 Side stream RO membrane installation method 

Take  the  water  purifier  out  of  the  package  carton.  Open  the  machine  cover.  Unscrew  the  nut  of  the 

membrane  housing cap  to  remove  the inlet  housing  pipe.  Open  the  housing  cap  by membrane housing 

wrench.  Check  if  the  vacuum  packing  of  RO  membrane  is  leaking.  If  not,  take  the  membrane  from  its 

packaging. Make sure there are 4 

“O” rings in one end of the membrane central tube and 2 “O” rings in the 

other end. Check whether there are expansion and deformation 

“O” rings, if not, insert the 4    “O” rings end 

into  the  membrane  housing  tightly(See  Diagram  9),  finally  ,  screw  the  housing  cap,  take  membrane 

housing wrench to tighten the cap. Insert the inlet pipe to the housing cap, screw the nut. Put the housing 

into the single clip and close the machine cover. 

   

 

Warnings: 

 

When installing the RO membrane you should pay attention to the direction of the membrane; 

 When installing the RO membrane, Make sure there are 4 

“O” rings in one end of the membrane central 

tube and 2 

“O” rings in the other end. Check whether there are expansion and deformation “O” rings

 

 When installing, be sure to insert the end with 4 O-rings into the membrane housing.    Be sure when 

installing to only use a little force to put the RO membrane into the membrane housing. If you encounter 

too  much  resistance,  please  do  not  force  the  reverse  osmosis  membrane  into  the  membrane  housing, 

doing  so  may  cause  permanent  damage  to  the  membrane  housing  or  membrane  components  (the 

manufacturer does not assume responsibility for returned components due to damage during installation); 

 Damage to the membrane housing and reverse osmosis membrane element caused as a result of the 

above reasons is not covered under the water purifier warranty. 

Summary of Contents for CR500-A-S-1

Page 1: ...e water you drink is cleaner and also beneficial to your health Before you install and use this water purifier please be sure to read the user manual this enables qualified and standardized installati...

Page 2: ...rations 8 Instructions for Proper Installation 8 Installation Notes 11 Troubleshooting Methods 12 Usage Methods 12 Maintenance and Upkeep 13 Flushing the RO Membrane 13 Filter Replacement Time 13 Filt...

Page 3: ...s Do not put heavy objects on the water purifier If heavy objects are placed on the water purifier it may result in damage to the water purifier s outer cover or internal components which could lead t...

Page 4: ...water discharge pipes and waste water ratio device are clogged it may lead to high TDS effluent the RO membrane may get blocked or the water purifier may not work Water purifier inlet water temperatur...

Page 5: ...5 Product Introduction 1 Blown up profile of the water purifier Diagram 1 2 Electrical Diagram Diagram 2...

Page 6: ...Protection Type Type II Suitable Water Quality Municipal tap water meeting the GB5749 2006 standards Note Due to product improvements the above parameters may change but the product nameplate shall st...

Page 7: ...g full It automatically shuts off the power source so the machine stops when pressure of pure water attains rated one 4 Inlet Water Solenoid Valve Connects or cuts off incoming water Operating pressur...

Page 8: ...head screwdrivers 1 of each Scissors 1 pair 14 16mm wrench 1 19 21mm wrench 1 Needle nose pliers 1 Confirm that you have all of the accessories required for installation Prior to installation turn off...

Page 9: ...ould be firmly in place otherwise leakage could occur Diagram 5 Diagram 6 Gooseneck faucet installation In the counter where the faucet is to be installed drill a 14mm hole in an appropriate position...

Page 10: ...he membrane housing tightly See Diagram 9 finally screw the housing cap take membrane housing wrench to tighten the cap Insert the inlet pipe to the housing cap screw the nut Put the housing into the...

Page 11: ...t be installed In addition for the water pipe bottom connector the screw nut should have no wire teeth exposed If the inlet water pipe is 9mm ensure that the inlet water pipe and connector have 30 40c...

Page 12: ...et 6 Wait some time to ensure everything is operating normally Then the water purifier can be used safely Usage Methods 1 The major components of this machine are plastic When using the product always...

Page 13: ...a three person family on average uses 10L of water a day according to the water volume and inlet water quality conditions overall filter volume is approximately as follows the following data is for re...

Page 14: ...ane component damage Do the following 1 Turn off the water purifier inlet water valve 2 Using the filter cartridge wrench remove the water purifier s third stage filter 3 Place a large container near...

Page 15: ...wastewater Replace the inlet water solenoid valve A pre filter is blocked Observe the output water and wastewater replace the pre filter The non return valve is blocked wastewater no output water Rep...

Page 16: ...the water source cut the power and contact your local vendor Notes The company reserves the right to change product design configuration and specifications without notice The company has final explan...

Reviews: