MEASUREMENT AND ASSEMBLY MANUAL 

Validity of  the manual: 1. 9. 2014 

 

  

 

APPLY  ONE  HALF  OF  THE  COUPLER  TO  EACH  END  OF  THE  CHAIN  AND  THEN  LOCK  BOTH  COUPLER 

HALVES. 

If a fixed tensioning system 

– pulley – is used: 

The pull cord length must be limited as follows: 

1)  If installation height (H0) is not specified, and 

i) if the blind height (H) is less than or equal to 2.5 m, the length of the pull cord(s) (H2) shall be less than or equal 

to 1 m (see Fig.

): H2 ≤ 1 m. 

ii) if the blind height (H) exceeds 2.5 m, the length of the pull cord(s) (H2) shall be less than or equal to the height 
of the blind minus the value of 1.5 m (see Fig. 6): H2 ≤ H - 1.5 m. 

2)  If installation height (H0) is specified, the distance from the floor to the bottom part of the pull cord(s) (H1) shall be 

at least 1.5 m (see Fig.): H1 > 1.5 m. 

b)  The distance between two loop strands shall not exceed 50 mm at the output from the fixed tensioning device. 

  

 

  

 

THE  PULLEY  POSITION  SHALL  PREVENT  EXCESSIVE  CHAIN  TENSIONING  AND  THE  CHAIN  MUST  NOT  COME 

OFF! 

WHEN PULLED APART, THE GAP BETWEEN THE CHAIN STRANDS SHALL NOT EXCEED 50 mm! 

Cord controls: 

The blinds shall meet the following requirements: 

If fully pulled up, the pull cord(s) length shall be limited (the two wheels shall be located as follows): 

If installation height (

H

0

) is not specified, and 

i) if the blind height (

H

) is less than or equal to 2.5 m, the length of the pull cord(s) (

H

2

) shall be less than or equal 

to 1 m (see Fig.): 

H

2

 

≤ 1 m. 

ii) if the blind height (

H

) exceeds 2.5 m, the length of the pull cord(s) (

H

2

) shall be less than or equal to the height 

of the blind minus the value of 1.5 m (see Fig.): 

H

2

 

≤ 

H

 - 1.5 m. 

Summary of Contents for SYSTEM 25

Page 1: ...chart with a tolerance of 1 mm It is recommended to consult with the manufacturer for dimensions outside the stated limits H height is measured the same as the width in three points including sealing...

Page 2: ...20 2 mm hole for tightening pin 3 2 mm for plastic and Al windows 3 mm for wooden windows INSPECTION before assembly we recommend inspecting all the parts after the delivery of the goods to prevent an...

Page 3: ...ndow Fig assembly from upwards Fig assembly from the front insert the nylon with the knot into the hole and press the pin When drilling these holes ensure that the span of the holes to the glazing bar...

Page 4: ...th the lever check the function of the blind ATTENTION Pursuant to the EN 13120 2014 standard window blinds shall be installed in accordance with the following instructions Chain If a breakaway couple...

Page 5: ...the bottom part of the pull cord s H1 shall be at least 1 5 m see Fig H1 1 5 m b The distance between two loop strands shall not exceed 50 mm at the output from the fixed tensioning device THE PULLEY...

Page 6: ...6 If installation height H0 is specified the distance from the floor to the bottom part of the pull cord s H1 shall be at least 1 5 m see Fig H1 1 5 m The pull cords shall meet the following requireme...

Page 7: ...EASUREMENT AND ASSEMBLY MANUAL Validity of the manual 1 9 2014 7 ILLUSTRATIVE ASSEMBLY OF THE BLIND WITHOUT THE COVER PROFILE ASSEMBLY ASSEMBLY WITH COVER PROFILE CONSTRUCTION CHAIN CORD HANDLE ENGINE...

Page 8: ...the glazing bar does not allow drilling holes to secure the tightening pins into the glazing bar from upwards choose the option of drilling the holes for pins into the face of the glazing bar In this...

Page 9: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 1 9 2014 9 ILLUSTRATIVE ASSEMBLY OF THE BLIND WITHOUT THE COVER PROFILE...