MEASUREMENT AND ASSEMBLY MANUAL 

Validity of  the manual: 1. 9. 2014 

…… (depth)

 depth of the glazing bar is measured in relation to the use of the distance pads under the plastic holders of 

the blinds. Left and right bases are not distinguished, depth of the window:  

20 mm and more no base  

16 

– 20 mm one base for each side  

12 

– 16 mm two bases for each side  

 

ATTENTION!. When measuring, check the shape and size of the glazing bar to prevent any problems during assembly of 

the guiding (tightening pins or fixed console). 

2. ASSEMBLY  

Assemble exactly according to this manual to prevent redundant assembly errors and other related problems.  

AIDS FOR ASSEMBLY:  

  electric drill, drills, cross-head screwdriver, knife, scissors, pliers  

For all wooden windows, the holes must be pre-drilled for the bolts, otherwise, there is a risk of cutting the glazing bar. The 

diameters of drills and types of screws are in the following table:  

 

screw

 

drill with the diameter Ø

 

for fixation of the blind with the cover profile 

3,9x16, 3,9x25 

3 mm 

for fixing the holder of the chain 

3,9x16 

3 mm 

hole for tightening pin 

3,2 mm for plastic and Al windows 

3 mm for wooden windows 

for fixation of the blind with the cover profile 

3,9x16 

3 mm  

for fixing the holder of the chain 

3x12, 3x20 

2 mm  

hole for tightening pin 

3,2 mm for plastic and Al windows 

3 mm for wooden windows 

 

INSPECTION:  

  before assembly we recommend inspecting all the parts after the delivery of the goods to prevent any problems. The 

manufacturer must be notified of any defects or comments concerning the assembly or blinds.  

ASSEMBLY WITH COVER PROFILE (CONSTRUCTION - CHAIN, CORD, HANDLE, ENGINE)  

  remove the upper cover profile (if mounted on the grid)  

  on the blind in the window wing check if its dimension corresponds to the width of the window; check that the control 

mechanism is on the right side. If it is necessary to be changed, it is not possible to change it for any System 25 blind. 

In this case, we recommend contacting the producer. Depending on the depth and shape of the glazing bar, support 

the blind using the pads. Place the blind to the window wing and screw each holder, using the two screws, into the 

glazing bar to prevent damage to the frame. The holders are attached to the upper profile in production to ensure the 

correct position during assembly of the blind on the window wing. If the blind is fitted with a brake (only in the version 

with a chain) there is a plastic holder between the gearbox and the brake which decreases the control force of the blind 

and prevents deformation. For the version with the handle, proceed similarly. By locating the holder closely behind the 

gearbox, it is possible to prevent deformation of the upper profile.  

Summary of Contents for SYSTEM 25

Page 1: ...chart with a tolerance of 1 mm It is recommended to consult with the manufacturer for dimensions outside the stated limits H height is measured the same as the width in three points including sealing...

Page 2: ...20 2 mm hole for tightening pin 3 2 mm for plastic and Al windows 3 mm for wooden windows INSPECTION before assembly we recommend inspecting all the parts after the delivery of the goods to prevent an...

Page 3: ...ndow Fig assembly from upwards Fig assembly from the front insert the nylon with the knot into the hole and press the pin When drilling these holes ensure that the span of the holes to the glazing bar...

Page 4: ...th the lever check the function of the blind ATTENTION Pursuant to the EN 13120 2014 standard window blinds shall be installed in accordance with the following instructions Chain If a breakaway couple...

Page 5: ...the bottom part of the pull cord s H1 shall be at least 1 5 m see Fig H1 1 5 m b The distance between two loop strands shall not exceed 50 mm at the output from the fixed tensioning device THE PULLEY...

Page 6: ...6 If installation height H0 is specified the distance from the floor to the bottom part of the pull cord s H1 shall be at least 1 5 m see Fig H1 1 5 m The pull cords shall meet the following requireme...

Page 7: ...EASUREMENT AND ASSEMBLY MANUAL Validity of the manual 1 9 2014 7 ILLUSTRATIVE ASSEMBLY OF THE BLIND WITHOUT THE COVER PROFILE ASSEMBLY ASSEMBLY WITH COVER PROFILE CONSTRUCTION CHAIN CORD HANDLE ENGINE...

Page 8: ...the glazing bar does not allow drilling holes to secure the tightening pins into the glazing bar from upwards choose the option of drilling the holes for pins into the face of the glazing bar In this...

Page 9: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 1 9 2014 9 ILLUSTRATIVE ASSEMBLY OF THE BLIND WITHOUT THE COVER PROFILE...

Reviews: