7 LEDs for diagnostics
The electronic control unit has a troubleshooting function when a LED is connected
as shown below.
The number of flashes indicates the type of error.
Number of LED
Flashes
Type of Error
Solution
6
Defective sensor (the sensor is defec
-
tive or disconnected).
Re-connect the sensor and verify that
the compressor starts working again.
Replace sensor if the compressor does
not work.
5
Thermal protection of the electronic
control unit
.
(the electronic control unit overheats
if the refrigeration system has become
overloaded or the environmental tem
-
perature is too high)
Remove excess gas or increase ventila
-
tion.
4
Minimum motor speed error.
(if the refrigeration system has been
overloaded, the motor cannot maintain
minimum speed of approximately
1.850 RPM).
Remove excess gas.
3
Motor starting error
[the rotor is blocked or pressure inside
the refrigerant circuit is too high (> 5
bar)].
Defective electronic control unit.
The first operation to attempt is to
replace the electronic control unit. Re-
place compressor if problem persists.
2
Fan short-circuited
(the fan absorbs more than 1A from
the electronic control unit).
Replace the fan.
1
Battery protection
(voltage is outside the maximum and
minimum voltages).
Check power cable conditions. Replace
with new cables if necessary. Check
battery conditions.
Summary of Contents for CR 130
Page 2: ......
Page 3: ...3 Isotherm Cruise Serie Fig 1 Fig 2...
Page 4: ...4 Isotherm Cruise Serie Fig 3 Fig 4...
Page 5: ...5 Isotherm Cruise Serie Fig 5 Fig 6...
Page 6: ...6 Isotherm Cruise Serie Fig 7 Fig 8...
Page 7: ...7 Isotherm Cruise Serie Fig 9 Fig 10...
Page 8: ...8 Isotherm Cruise Serie Fig 11 Fig 12...
Page 218: ...218 1...
Page 219: ...219 INDEL Webasto Marine S r l 1 2 2002 96 RAEE...
Page 220: ...220 R134a R134a R134a 1 3 Indel Webasto Marine S r l...
Page 221: ...221...
Page 222: ...222 115 230 8...
Page 223: ...223 2 SN 10 C 32 C N 16 C 32 C ST 16 C 38 C T 16 C 43 C 2 1 5 6 C...
Page 224: ...224 2 2 6 Indel Webasto Marine S r l 30...
Page 225: ...225 2 3 3 4 0 3 Isotherm Cruise Cruise Elegance 0 C...
Page 227: ...227 4 Indel Webasto Marine S r l...
Page 228: ...228 EN 603 335 1 5 Heavy Current Regulations 115 230...
Page 235: ...235 6 T C R134a...
Page 236: ...236 4 4 C P C T...
Page 237: ...237 Indel Webasto Marine Isotherm...
Page 238: ...238 7 6 5 4 1 850 3 5 2 1A 1...
Page 241: ...241 9 Indel Webasto Marine 1999 44 Isotherm 2 IWM b S N...
Page 243: ...243 Isotherm Cruise Standar Cruise DC 12 24 Volt...
Page 244: ...244 Isotherm Cruise Standar Cruise AC DC 12 24 Volt 115 230 Volt...
Page 245: ...245 Isotherm Cruise Cruise CR130 DRINK DC 12 24 Volt...
Page 246: ...246 Isotherm Cruise Cruise CR130 DRINK AC DC 12 24 Volt 115 230 Volt...
Page 247: ......