Isokern VF-36 Installation, Operation, Maintenance And Owner'S Manual Download Page 16

Warranty & Disclaimer

Isokern Fireplace 

Earthcore  offers  a  lifetime  warranty  for  all  Isokern  fireboxes,  to  be  free  from  defects  in  materials  that  

negatively affect system performance from the date of purchase, subject to the terms and conditions of this 

limited warranty.

This warranty covers only the above stated components, and NO WARRANTY, EXPRESS OR IMPLIED,

EXTENDS TO ANY OF THE HARDWARE, FOOTING, VENTS, DUCTING, METAL FLUES, FIRE 

BRICK OR ACCESSORIES. THIS WARRANTY DOES NOT COVER DRAFTING, SMOKING OR 

UFFING OF THE FIREPLACE SYSTEM. Factors beyond the manufacturer's control affect fireplace 

rafting, smoking, and puffing, and Earthcore cannot guarantee these aspects of performance.

If a component is found to be defective under the terms of this warranty the party to whom this warranty is

extended shall, notify Earthcore, 6899 Philips Industrial Blvd, Jacksonville, Florida 32256, in writing, by

registered mail, within thirty (30) days following the discovery of the defect within the lifetime warranty 

period. The notice shall contain (1) the date of purchase; (2) place of purchase; (3) address of installation; 

(4) name, address and phone number of the owner; and (5) a brief description of the defect.

Earthcore, or any division thereof, is not responsible for any labor costs or indirect costs incurred for the 

replacement of defective components.

Earthcore is not responsible for misuse or mishandling of components. Nothing in this warranty makes 

Earthcore, or any division thereof, liable in any respect for any injury or damage to the building or structure 

in which the fireplace or chimney system has been installed or to persons or property therein arising out of 

the use, misuse, or installation of properly manufactured ISOKERN product.

EARTHCORE, OR ANY DIVISION THEREOF, SHALL NOT BE HELD LIABLE FOR ANY INCIDENTAL 

OR CONSEQUENTIAL DAMAGES OR EXPENSES ARISING OUT OF THE USE OF THE FIREPLACES 

OR CHIMNEY SYSTEMS. ALL SUCH DAMAGES AND EXPENSES ARE HEREBY EXCLUDED.

This warranty is null and void when the fireplace or chimney systems are not installed pursuant to the 

installation instructions provided by Earthcore or local building codes have not been followed completely.

This warranty applies only to those fireplace and chimney systems installed in the continental United 

States, Alaska, and Canada. If any part of this warranty is found to be unenforceable, the remaining parts 

shall remain in force and effect.

EARTHCORE HEREBY DISCLAIMS ALL GUARANTEES AND WARRANTIES, EXPRESS OR 

IMPLIED, BEYOND THE WARRANTIES SET FORTH HEREIN.

6899 PHILIPS INDUSTRIAL BLVD. • JACKSONVILLE, FLORIDA 32256

TEL (904) 363-3417 • TOLL 1 (800) 642-2920 • FAX (904) 363-3408

Summary of Contents for VF-36

Page 1: ...cit installation and operation instructions INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Be Sure to Read Entire Manual Before Beginning Construction Contents of this manual may change without prior notification FOR USE ONLY WITH DECORATIVE TYPE CERTIFIED VENT FREE GAS LOG DO NOT BUILD A WOOD FIRE Carefully review the instructions supplied with the...

Page 2: ...n 11 Specialty Application 12 See Thru 12 Noncombustible Finished Facing Requirements Clearance to Combustible Trim 13 Summary 14 Notes 15 Warranty Note Illustrations shown in this manual are not to scale and are intended to show typical installations Nominal dimensions are given for design and framing reference only since actual installations may vary due to job specific design preferences Howeve...

Page 3: ...on However all such trim material must meet standard fireplace code requirements non combustible facing material must be applied to a minimum of eight inches 8 beyond the sides of the finished opening of the Vent Free fireplace and non combustible facing material must cover a minimum of twelve inches 12 above the finished opening of the installed unit Reference Intertek Testing Services Report No ...

Page 4: ...1 2 3 20 5 A C 25 B Model A B C 36 43 36 1 8 27 1 4 42 49 43 1 8 46 53 47 1 8 33 1 4 37 1 4 37 1 2 43 W x 37 1 2 H x 25 1 4 D 49 W x 37 1 2 H x 25 1 4 D 53 W x 37 1 2 H x 25 1 4 D MINIMUM FRAMING 715 lbs 820 lbs 880 lbs WEIGHT B See Thru Models Side View Front View Plan View 3 31 1 37 1 ...

Page 5: ... Size 36 42 46 Quantity 3 3 3 BASE TOP PLATE Model A 36 43 42 49 46 53 SIDE WALL BACK WALLS Model A 36 43 42 49 46 53 A 10 1 2 2 5 10 1 2 2 5 3 5 Earthcore reserves the right to make changes at any time without notice in design materials and specifications Earthcore further reserves the right to discontinue styles and products Please call 1 800 642 2920 for an Isokern dealer near you ...

Page 6: ...trim Since this weight is spread over an area of seven and one half square feet 7 5 sq feet to nine and one half square feet 9 5 sq feet depending on standard unit size chosen it is necessary that any wood floor framing where this unit is placed be designed to carry concentrated loading of approximately 150 lbs sq foot Standard residential concrete slab is a suitable foundation This may be either ...

Page 7: ...es B Framed Opening A Framed Opening C The following chart of dimensions is intended to aid in the positioning of a Vent Free fireplace in a corner condition Firebox A B C D Model 36 43 49 3 4 32 1 2 49 Model 42 49 52 3 4 37 71 3 4 Model 46 53 54 3 4 39 1 2 74 1 2 Notes A A reflects the Vent Free Series base plate dimension B B reflects the Vent Free Series outside center of firebox base plate to ...

Page 8: ... mating components are assembled Face and Surface Cracks Should a face crack appear after the unit is assembled the crack can be repaired in place A crack can be V notched with a masonry chisel to a depth of approximately three eighth inch 3 8 Earthcore Mortar is then squeezed into the face crack and troweled smooth to the surface of the component Note Badly fragmented components should be discard...

Page 9: ... plus the one and one half inch 1 1 2 thick fire brick floor in addition to the height of the concrete block platform For a flush hearth fireplace floor flush with the room s floor the base plate can be omitted from the assembly and the firebox walls built directly on the concrete support slab as long as there are no wood underpinnings This makes the fireplace finished fire brick floor approximate...

Page 10: ...rbon monoxide detector be installed Gas line for gas log sets used in the Vent Free firebox can be routed through the side wall back wall or floor of the firebox by drilling an appropriately sized hole using a masonry drill bit Electrical Line Feed can be routed through the firebox back wall side walls or floor by drilling an appropriately sized hole using a masonry drill bit Be sure to follow the...

Page 11: ...d It takes a total of about five gallons of mortar mix dry measure to fire brick line a Vent Free Face joints of one quarter inch 1 4 to three eighths inch 3 8 give a good appearance to the finished brick work however larger face joint dimensions are also acceptable Step 1 Wet mop the inside of the Vent Free with a damp sponge to remove dust and loose particles from the interior before installing ...

Page 12: ...or two sided Vent Free fireplaces can be constructed from the standard one sided unit components by eliminating the back wall assembly In this installation the standard side wall components are reversed so that the standard side wall taper sits to the outside of the box leaving the inside of the see thru firebox with two straight and parallel interior walls Angle steel three inch by three inch by ...

Page 13: ...asure of twenty four inches 24 away from the finished opening of the Vent Free fireplace Mantle and Mantle Shelf Clearance Vent Free fireplace are subject to the same building code safety clearances from the firebox opening as with any fireplace opening Parts of the combustible mantle assembly located above and projecting more than one and one half inches 1 1 2 inches from the firebox opening shal...

Page 14: ...anufacturer s agent or supplier Dual Listed Appliance The Vent Free fireplace is certified with the use of dual listed unvented gas log heaters with a maximum input of 40 000 Btu s Do not burn any other type of vented gas log fire wood paper or refuse in the Vent Free fireplace Fuel Do not introduce any type of fuel into the Vent Free fireplace other than the LP or Natural Gas listed for use in th...

Page 15: ...15 Notes ...

Page 16: ...ision thereof is not responsible for any labor costs or indirect costs incurred for the replacement of defective components Earthcore is not responsible for misuse or mishandling of components Nothing in this warranty makes Earthcore or any division thereof liable in any respect for any injury or damage to the building or structure in which the fireplace or chimney system has been installed or to ...

Reviews: