25 ¼”
B
A
C
Model
A
B
C
36”
43”
36 1/8”
53”
42”
49”
43 1/8”
59”
46”
53”
47 1/8”
63”
12
Specialty Applications: See-Thru
The firebox side walls must sit three inches (3”)
on the base plate. Since the side wall components flair from
three inches (3”) at the narrow end to eight inches (8”) on
the wide end, the side walls will overhang the base plate by
approximately five inches (5”) at their wide end. Support this
overhang with masonry.
See-Thru or two-sided Vent-Free fireplaces can be
constructed from the standard one-sided unit components by
eliminating the back wall assembly.
In this installation the standard side wall components
are reversed so that the standard side wall taper sits to the
outside of the box leaving the inside of the see-thru firebox
with two straight and parallel interior walls.
Angle steel three inch by three inch by one quarter
inch (3” x 3” x 1/4”) should be set on top of the side wall
assembly to span each of the openings of the see-thru before
the top plate is set into place.
The steel can be set with the angle leg either up or
down.