25 1/2”
DISCAR
D
65 1/2
”
49 3/4”
30
Assembly Instructions - 72” (cont.)
Note:
The MAGNUM model 72 is designed to operate
with two flues. The top of the smoke dome allows for the
placement of two Isokern DM 54 (14 inch I.D.) chimneys or
two solid fuel listed metal chimneys of the appropriate size.
Step 22:
Top plate small, part M77, two required, to be used
“as is”. (Figure 68)
Place the two top plate small components on top of
the second tier smoke dome arrangement so that they meet at
the centerline of the smoke dome. Typically, the outlet hole
sits closer to the back of the smoke dome. The top plates
should sit flush with the front and back of the smoke dome.
(Figure 69).
The top width dimension of the completed smoke
dome should measure 65-1/2”.( Figure 66) Each top plate
small has a width dimension of 32-3/4 inches. Two of the
top plates butted together should equal the smoke dome top
width dimension of 65-/12”. (Figure 69)
The top plates should be flush with the top sides of
the smoke dome assembly. Minor overhang (fractions of an
inch) of the top plate assembly is acceptable.
FIGURE 65
FIGURE 66
FIGURE 67
FIGURE 68
FIGURE 69