Remote Control System
Remote Control System
The Remote allows you to command the functions of your appliance from the comfort of your chair and is configured
to control the On/Off primary burner operation, its flame height through six (6) levels, and provides On/Off control of the
appliance.
(Figure 56)
The system controls blower speed through six (6) levels and has a constantly powered 120V/60Hz power outlet. The
remote sends commands via radio frequency from the Remote(transmitter) and does not require line-of-sight operation.
Install the remote control system
Required Items (not provided):
1.
Standard Junction Box
2.
Paper Clip or similar object (for remote control system initialization)
The receiver for the remote control system connects directly to the gas valve, stepper motor, and fan control module with
an umbilical cord wiring harness.
1.
Install a junction box (not provided) on the wall adjacent to the appliance, within reach of the remote system umbilical cord
wiring harness.
2.
Position the terminal within the junction box in preparation for attachment to the remote wall switch.
3.
When wall finish is complete, install the wall switch in the previously installed junction box, and connect the terminal to the
connector on the back of the wall switch.
4.
Install the wall switch cover plate, taking care to ensure the wall switch is properly indexed with the switch cover when
aligning the components for attachments.
Initializing The System For The First Time
1.
Insert the three (3) provided AAA batteries into the battery bay in the transmitter. Correctly align polarity (+/–).
2.
Insert the four (4) provided AA batteries into the wall switch battery bay (behind the wall switch plate). Correctly align polarity
(+/–).
3.
On the wall switch, place the three-position slider switch in the REMOTE position (Figure 28).
4.
On the wall switch front cover, insert the end of a paper clip (or other similar object) into the hole marked PRG.
NOTE:
The Receiver will beep three (3) times to indicate it is ready to synchronize with the transmitter.
5.
On the transmitter, press the ON button. The receiver will beep four (4) times to indicate acceptance of the transmitter’s
command (and set the receiver to the transmitter’s specific code). The system is now initialized.
Low Battery Power Detection
The life span of the Receiver batteries depends on various factors: quality of the batteries used, the number of ignitions of the
appliance, the number of changes to the room thermostat set point, etc.
When the Receiver batteries are low, two “beeps” will be emitted from the Receiver when it receives an ON/OFF
command from the Remote.
This is an alert for a low battery condition for the Receiver. When the batteries are replaced the “beep” will be emitted
from the Receiver when the ON/OFF key is pressed (See Initializing The System).
WARNING:
Fire hazard. Can cause severe injury or death. The receiver causes ignition of the appliance. The appliance can
turn on suddenly. Keep away from the appliance burner when operating the remote system or activating manual bypass of the
remote system.
WARNING:
Property damage hazard. Excessive heat can cause property damage. The appliance can stay lit for many hours.
Turn off the appliance if it is not going to be attended for any length of time. Always place the Transmitter where children cannot
reach it.