![Isokern 82L120 Installation, Operation, Maintenance And Owner'S Manual Download Page 20](http://html1.mh-extra.com/html/isokern/82l120/82l120_installation-operation-maintenance-and-owners-manual_2093403020.webp)
20
Earthcore Industries
Isokern Maximus Linear Series Gas Fireplace
01/2020
5.
Continue assembly of the consecutive courses of the firebox side wall and back wall,
making sure to stagger the
back wall components so that the vertical joints do not align.
Apply Earthcore Adhesive to the top of each layer of
wall components, set the next course above into place. Be sure to apply Earthcore Adhesive to all vertical joints of the
side wall to back wall connection when setting each component to its mate
(Figure 12).
Look for some Earthcore Adhesive to squeeze out along the joints of all contact surfaces as a sign that the joint is
thoroughly sealed with the approved Earthcore Adhesive.
6.
When all of the firebox side wall and back wall components are set, check the top surface of the firebox for level. If
necessary, adjust the top surface of the box assembly for level by inserting a shim supplied with the unit between the
lowest wall component and the top surface of the base plate.
Any gap created under the wall components during the shim leveling process must be filled with Earthcore Adhesive
to fill bearing against the base plate.
7.
Steel angle iron with measurements of 6” x 6” x 1/2” cut to span firebox opening will be needed to assemble the 72”,
96” and 120 fireboxes.
The 48” Model does not require a Steel Angle for installation. This item is not included in
the components and can be sourced locally.
This steel angle sits on top of the uppermost side wall component with the 6” leg in the horizontal position. To avoid a
thickness problem with the placement of the steel angle, it is necessary to cut a notch approximately 1/2” deep in the top
side wall component where the angle is to sit. The notch should start at the front face of the side wall component (at both
the left and right hand walls) and run to a point 6” back toward the firebox
(Figure 12).
Maximus Linear Glass Front Kit Installation
M90
M90
FIGURE 12
Backwall Course:
48": Part# M67
72": Part# 73, 72
96": Part# 160, 162, 73
120": Part# 71,162,162, 73
PROJECT:
MATERIAL:
SIZE:
APPROVED:
DESCRIPTION:
UNLESS OTHERWISE STATED, ALL
DIMENSIONS ARE IN MILLIMETERS
ANG. .X
THIRD ANGLE
PROJECTION
.X
.XX
X
LIN.
DRAWN:
D
SCALE:
DO NOT SCALE
OF
DATE:
DATE:
REV:
DRAWING #:
SHEET #
UNSPECIFIED
TOLERANCES
±
±
±
±
6899 Phillips Industrial Blvd.
Jacksonville, Fl. 32256
8' LINEAR
EXPLODED VIEW FOR MANUAL: STEP 5
E.C. PUMICE MIXTURE
K.B.H
N.T.S
82L96
1
1
6"
1/2"
6" x 6" x 1/2"
STEEL ANGLE