11. Scheduler
The features described in this chapter are not available on the "Light" models.
The main power socket can be controlled in the automatic mode, based on pre-
scheduled rules. Some other commands could be executed at pre-defined intervals. For
example, enable/disable Alarm Function or regularly send status of the device. The
schedule accepts a maximum of 8 rules.
Command
Description
Response
Type
SChh:
mm,day,action
This command adds a new rule for a specified
time valid for all days within a week
SChh:mm,*,
ON – OK
Ctrl
SCHEDULER-hh:mm
Delete record for configured time
SCHEDULER-hh:mm - OK Ctrl
SCHEDULER-ALL
Remove all tasks
SCHEDULER-ALL - OK
Ctrl
SCHEDULER?
Request for scheduler configuration
11:59,*,AON
Inf
* = any day; 1=Monday, 2=Tuesday, 3=Wednesday, 4=Thursday, 5=Friday, 6=Saturday, 7=Sunday
Actions: ON=Turn on, OFF=Turn off, INF=Send status of iSocket (STATUS command execute), AON=Alarm function
activation (premises will be under surveillance),
AOF= Alarm function deactivation (disable premises protection)
Examples:
SC08:00,*,ON
Turn on main power socket every day at 8:00
SC20:30,*,OFF
Turn off main power socket every day at 20:30
SC09:00,1,AON
Activate Alarm function every Monday at в 09:00
SC18:00,5,AOF
Disable Alarm function every Friday at в 18:00
SC17:00,6,INF
Send status of iSocket every Saturday at 17:00
Status information is sent to the number specified by command
ALER
(see Chapter 7.3).
12. Status After Resumption of Power Supply
These settings are stored in non-volatile memory and are not upset by power supply
interruptions.
Command
Description
Response
Type
POWERSTATE=REME
MBER
The main power socket remembers its state
and returns to it after the resumption of power
supply to the device
POWERSTATE=REMEMB
ER – OK
Conf
POWERSTATE =ON
The main power socket always turns on when
resuming power supply to the device
POWERSTATE=ON – OK Conf
POWERSTATE =OFF
Main power socket is always turned off when
resuming power supply to the device
POWERSTATE=OFF –
OK
Conf
POWERSTATE?
Information about POWERSTATE configuration
POWERSTATE=(REMEM
BER), ON, OFF
Inf
iSocket
®
Power Notifier
iSocket
®
Power Notifier - a feature of the iSocket device which will notify you in the
event of a power failure and/or the restoration of the power supply.
This feature is available on the "707" models, which have a built-in rechargeable
battery. Some "706" models partially support this feature and can inform you of the
restoration of power supply, but cannot inform of interruptions of power, since they do
not have a built-in battery. The availability of this feature on the "706" models cannot
be guaranteed.
To receive such alerts you need to configure the number for alerts using the command
ALERTNUMBER. Description of this command can be found in Chapter 7.3. Once this
number has been configured you will receive messages whenever power is interrupted