iSocket
®
GSM 706/707
www.isocket.eu
© Copyright Intellectronics 2012
All rights reserved. Version 1.1.2-EN
- 19 -
English
9.2 Sensor Activity Alerts - iSocket
®
Alarm Notifier
iSocket
®
Alarm Notifier
-
a feature of the iSocket device which will notify you in the
event of a break-in and some other case. You can receive notifications in various ways.
iSocket GSM 706/707 can call you or send an SMS when the sensor is triggered. You
can also be informed by SMS on each change of sensor's status (change of logical
value).
If you have configured notifications by messages the device will send messages to all
numbers. If call alerts are configured, the device will call you within about 20 seconds. If
you pick up the handset the microphone will be activated and you will hear sounds from
the room. If you don't pick up after 20 seconds the device will try to reach the next
number on the list. The device will only try to call each number once. The call-
notification cycle is considered complete as soon as someone answers or hangs up. If no
number is reached during the call-cycle, the device will send messages to all alert-
numbers, thus completing the notification cycle. SMS-notification cycle is considered
complete as soon as all messages have been sent by the device. Therefore the most
important numbers for notifications have to be placed at the beginning of the list.
Only one alarm within 60 seconds is indicated. This means that if two (or more) sensors
were activated within one minute, you will only get the one alert. During the notification
cycle the device will not detect new sensor triggering. The device will be ready to detect
sensor activity no later than one minute after completion of the notification cycle. If the
sensor is still active at this time the device will start a new session of notifications.
For these reasons the
ALERT=CALL/SMS
is the ideal option for many PIR sensors, which
changes its logical "0" to logical "1" value and back to "0". In this case only one alert is
generated and you receive a notification. However, this setting is not suitable, for
example, for door sensors which change their logical state from "0" to "1" and stay in
this state. Since they remain in this state you will receive endless alerts until you
deactivate the alarm function with the command
ALARMOFF
. For sensors that change
their status and stay in that status, the option
ALERT=SMSCHANGE
was designed. With
this configuration you will be notified only once - when a logical value is changed.
The microrelay will be active for the time configured by command MICRORELAYTIME.
However it will be deactivated as soon as someone picks up the phone during the call-
notification cycle. The microrelay is active only if the alarm function is active.
Command
Description
Response
Type
ALERT=CALL
Notify by phone call to predefined number when the
sensor is triggered
ALERT=CALL - OK
30min
ALERT=SMS
Send SMS to predefined number when the sensor is
triggered
ALERT=SMS – OK
30min
ALERT=
SMSCHANGE
Send SMS to predefined number when the sensor's
status is changed (logical value was changed)
ALERT=SMSCHANGE – OK
30min
ALERT=OFF
Disable alerts. (This is useful if you want just to
activate Micro relay when sensor was triggered)
ALERT=OFF - OK
30min
ALERT?
Information about ALERT configuration
ALERT=(SMS),CALL,SMSCH
ANGE, OFF
Inf
Summary of Contents for GSM 706