background image

4

 

 

3

 

Product

 

Reglo

 

ICC

 

is

 

a

 

peristaltic

 

pump

 

with

 

independently

 

controllable

 

channels.

 

The

 

intended

 

use

 

for

 

this

 

pump

 

is

 

precise

 

fluid

 

dispensing

 

at

 

low

 

flow

 

rates

 

up

 

to

 

43ml/min

 

for

 

fluid

 

delivery

 

applications.

  

Contents

 

of

 

the

 

package

 

 

 

Reglo

 

ICC

 

Pump

 

(type

 

as

 

ordered)

  

 

1

 

power

 

supply

 

 

3

 

cassettes

 

 

1

 

power

 

cord

 

with

 

country

 

specific

 

plug

 

 

Operating

 

manual

 

 
 
 
 
 
 

Please

 

check

 

the

 

package

 

and

 

its

 

contents

 

for

 

transport

 

damage.

 

If

 

you

 

find

 

any

 

signs

 

of

 

damage,

 

please

 

contact

 

your

 

local

 

ISMATEC

®

 

representative

 

immediately.

 

4

 

Rear

 

Panel

 

1.

 

24VDC

 

power

 

Inlet

 

plug

 

2.

 

On

 

/

 

Off

 

Switch,

 

circuit

 

breaker

 

3.

 

RS

232

 

In,

 

DB9

female

 

4.

 

RS

232

 

Out,

 

DB9

male

 

5.

 

USB

 

2.0,

 

Mini

B

 

5

 

Main

 

Voltage

 

Use

 

only

 

the

 

supplied

 

power

 

supply

 

and

 

cord

 

for

 

your

 

Reglo

 

ICC

 

pump.

  

DO

 

NOT

 

use

 

any

 

other

 

substitutes

 

or

 

damage

 

may

 

occur!

  

The

 

power

 

supply

 

is

 

designed

 

to

 

provide

 

DC

 

voltage

 

for

 

your

 

Reglo

 

ICC

 

pump.

  

It

 

has

 

built

 

in

 

circuit

 

over

 

current

 

protection

 

in

 

the

 

event

 

the

 

pump

 

is

 

overloaded

 

or

 

a

 

malfunction

 

occurs.

 

The

 

power

 

supply

 

is

 

connected

 

to

 

the

 

pump

 

by

 

a

 

4

pin

 

power

 

DIN

 

snap

 

and

 

lock

 

plug.

 

Appliance

 

coupler

 

of

 

the

 

power

 

supply

 

is

 

used

 

to

 

disconnect

 

the

 

device

 

from

 

the

 

mains

 

supply.

 

 

Voltage

 

100

264VAC

 

 

50

 

/

 

60

 

Hz

  

6

 

Pump

 

Operation

 

6.1

 

Key

 

Pad

 

and

 

Screen

 

1.

 

Run

 

/

 

Stop

 

Button

 

a.

 

Starts

 

and

 

stops

 

the

 

pump

 

b.

 

Interrupts

 

and

 

resumes

 

a

 

dispensing

 

cycle

 

2.

 

Reset

 

Button

 

a.

 

Escape

 

out

 

of

 

editing

 

a

 

parameter

 

without

 

changing

  

b.

 

Resets

 

dispensing

 

cycle

 

when

 

pump

 

is

 

paused

 

3.

 

Directional

 

Arrows

  

a.

 

Used

 

to

 

navigate

 

screen

 

and

 

highlight

 

selections

 

b.

 

Up,

 

down,

 

left,

 

right

 

4.

 

OK

 

/

 

Enter

 

Button

 

a.

 

Press

 

to

 

edit

 

parameter

 

b.

 

Saves

 

edit

 

to

 

parameter

 

once

 

complete

 

5.

 

LCD

 

Display

 

2.

 

1.

 

4.

 

3.

 

5.

 

1.

2.

 

4.

 

3.

 

5.

Summary of Contents for Reglo ICC

Page 1: ...zards cannot be excluded IDEX Health and Science LLC is not liable for any damage resulting from the use of an ISMATEC pump IDEX Health and Science LLC is not responsible for the unsafe handling of chemicals IDEX Health and Science Home of Upchurch Scientific and Ismatec Products 619 Oak Street Oak Harbor WA 360 679 2528 ...

Page 2: ... 6 4 2 PUMPING Menu 6 6 4 3 SETUP Menu 8 6 4 4 CALIBRATION Menu 9 6 4 5 GLOBAL SETTINGS Menu 10 6 5 Installing Tubing 10 6 6 Information Screens 10 6 7 Differential Pressure 10 6 8 When the Pump is Idle 11 7 Over Current Protection 11 8 Cassettes 11 9 Repair 12 10 Cleaning 12 11 Disposal 12 12 Technical Specifications 13 13 Tubing Size and Flow Rate Chart 14 14 IDEX Reglo ICC Serial Command Protoc...

Page 3: ...ation The necessary safety measures based on the specific situation must be taken When pumping corrosive media we recommend placing the pump in a collecting basin The pump should not come in contact with liquid Do not open or remove the housing while the pump is operating Service and repairs carried out by the customer or by third party companies voids all warranties Appliance coupler of the power...

Page 4: ...eglo ICC pump DO NOT use any other substitutes or damage may occur The power supply is designed to provide DC voltage for your Reglo ICC pump It has built in circuit over current protection in the event the pump is overloaded or a malfunction occurs The power supply is connected to the pump by a 4 pin power DIN snap and lock plug Appliance coupler of the power supply is used to disconnect the devi...

Page 5: ...r will then highlight the entire value exiting the edit mode When highlighting pumping modes tubing ID and language the OK Enter button will allow the parameter to be changed by toggling through a list using the directional arrows Once the selection has been made pressing the OK Enter button will save the selection and exit the editing mode The Run Stop button is used to start or stop all the chan...

Page 6: ...gh the three status screens 6 4 2 PUMPING Menu The PUMPING Menu allows you to set up the pumping parameters for all of the available channels The channel number that is being programmed is indicated in the upper right hand corner You can select the rotation direction pumping mode and values for each channel in the PUMPING menu 6 4 2 1 Flow Rate Mode Flow Rate Mode provides a continuous operation a...

Page 7: ...Selectable volume units are µl ml and L Only flow rate can be changed during pumping or when the operation is paused Dispensing program can be reset during operation by pressing the Reset button after pumping is paused 6 4 2 4 Time Mode Time Mode allows the user to dispense for a set time duration with a set flow rate Adjustable parameters are rotation direction flow rate flow rate units time and ...

Page 8: ... units are RPM µl min ml min and L min Selectable time units are sec min and hours Selectable pause time units are sec min and hours Only flow rate can be changed during pumping or when the operation is paused Dispensing program can be reset during operation by pressing the Reset button after pumping is paused 6 4 2 7 Disabled Mode Disabled Mode disables the selected channel for pumping The channe...

Page 9: ...a container Measure the actual amount of the fluid by weight or volume and enter that value on the last screen to adjust the pump for your application The calibration can be interrupted by pressing Run Stop button which will cancel the existing progress New uninterrupted calibration run will be required in order to calibrate the channel properly When adjusting the dispense time for calibration if ...

Page 10: ...ned and aligned well between dedicated segments on the bars 8 Turn the pump on 9 When the pump is idle release all cassettes to maximize tubing life beware of siphoning or back flow 6 6 Information Screens Indicates that the pump is being remotely controlled by a PC via USB connection Indicates that the internal temperature has exceeded a safe threshold and pumping will stop automatically to prote...

Page 11: ...tive immediately 8 Cassettes Your Reglo ICC can use the Click n Go cassettes or the pressure lever cassettes When using new tubing for the first time it may occur that depending on the tubing used hardness and diameter the pump cannot be primed and hence does not deliver the liquid If that is the case we recommend you wet the tubing and run the pump with the tubing inserted for about 15 to 30 minu...

Page 12: ...the beginning of the operation yet the individual flow rates may increasingly diverge at a later stage For an optimum long term flow rate stability and channel to channel conformity we suggest using the Click n Go cassettes 9 Repair The Reglo ICC is designed for many years of trouble free service The Reglo ICC does not have any fuses or adjustments inside the pump If you wish to attempt any repair...

Page 13: ...of any queries Specifica Motor l min steps of 0 01 digital interfac on 60 Hz C 41 to 104 normal labora mm 8 1x5x6 CE comp This Prod second e incorpor Pinch po General you observe please conta ations P rpm ces 4 F atory conditio 7inch patibility appr duct has been edition includi rating the sam oint warning warning our Warranty act your local Patent Pe ns oved accordin n tested to the ing amendme m...

Page 14: ...3 0 017 1 7 0 57 SC0054 0 021 2 1 0 64 SC0055 0 026 2 6 0 76 SC0056 0 036 3 6 0 89 SC0057 0 049 4 9 0 95 SC0058 0 056 5 6 1 02 SC0059 0 063 6 3 1 09 SC0060 0 072 7 2 1 14 SC0061 0 078 7 8 1 22 SC0062 0 088 8 8 1 3 SC0063 0 10 10 1 42 SC0064 0 11 11 1 52 SC0065 0 13 13 1 65 SC0066 0 15 15 1 75 SC0067 0 16 16 1 85 SC0068 0 17 17 2 06 SC0069 0 20 20 2 29 SC0070 0 24 24 2 54 SC0071 0 27 27 2 79 SC0072...

Page 15: ...acter Definitions The following symbols are used in the message definitions in this document SP space 0x20 CR carriage return 0x0d LF line feed 0x0a Definitions default command response message Set Address Command Direction PC to pump This is a specially formatted command used to set the address of each pump By default each pump uses address 1 The character ASCII 0x40 Addr The new pump address 1 8...

Page 16: ...nds is described in the Direct Addressed Command List below Addr The address of a pump to send a command to 1 8 Command Individual commands with an optional argument as defined in the Direct Addressed Command List below CR A carriage return character ASCII 13 Direct Addressed Command List Ref Command Argument Function Op Response General Information 1 Reset an overload condition Set Drive Control ...

Page 17: ... time too short Parameter Control 18 E Returns whether the pump is currently running or not Get running stopped 19 Returns the following fields each separated by a space Pump model description variable length A text field describing the model of pump This description may contain spaces Pump software version 3 digits The version of software currently running in the pump Pump head model type code 3 ...

Page 18: ...current setting for pump time in minutes 0 999 Format is 0HTU Set 30 VH 3 time setting Set the current setting for pump time in hours 0 999 Format is 0HTU Set 31 U Get the current setting for volume to pump in roller steps Get 100 CR LF 32 U 5 roller steps Set the current setting for volume to pump in roller steps 0 65535 Set 33 u 4 5 high order roller steps Use to set the current setting for volu...

Page 19: ...48 4 Set the current setting for pump cycles Format is THUT Set 49 Get the total trip volume pumped since the last reset in ul ml or liters Get 4 983 SP ml CR LF 50 W Reset the total trip volume count Set 51 Force the pump to save its current pump settings values time pause time speed backsteps cycle count etc to non volatile memory They will be available after device power down Set 52 0 Sets all ...

Page 20: ...iameter to 3 45 mm Get current pump time setting The current pump time setting is 10 5 seconds Set the current flow rate setting to 0 012 ml min 1200E 2 CR LF Response 1f1200 2 CR Command 105 CR LF Response 1T CR Command Response 1 0345 CR Command Response 3 0412 CR Command ...

Reviews: