![Islandaire 6041228 Installation And Operation Manual Download Page 10](http://html1.mh-extra.com/html/islandaire/6041228/6041228_installation-and-operation-manual_2093137010.webp)
Wiring Tips
Power Connections
The thermostat can be either battery
powered, or hard-wired to power by
connecting supply voltage wire (red) and
common wire to the RH and C terminals,
respectively, on the base.
Note: Installing batteries will enable the
thermostat to remember the program
that you have set even if there has been a
power outage.
Installation Tip
Electrical Hazard
Failure to disconnect the power
before beginning to install this
product can cause electrical shock or
equipment damage.
Note:
When connecting the 6041228
thermostat to a PTAC, refer to the
PTAC unit’s instructions to enable
remote thermostat operation.
Wire Specifications
Use shielded or non-shielded
18-22 gauge thermostat wire.
Remote Temperature Sensor
Connections
Use the S1 and S2 screw terminals to
connect the optional indoor remote
temperature sensor (Islandaire part no.
6040912). Indoor remote sensor wires
must be separated from the thermostat
wires.
Warning:
All components of the control
system and the thermostat
installation must conform to
Class ll circuits per the NEC Code.
THERMOSTAT
REMOTE TEMPERATURE
SENSOR
P/N 6040912
S1
S2
8
Wiring
Summary of Contents for 6041228