Islandaire 6041206 Installation And Operation Manual Download Page 9

R
Y

W

C

GL

GH

C

R

L1
L2

COMPRESSOR

RELAY

HEAT RELAY

FAN LOW RELAY

FAN HIGH RELAY

1

C

R

L1
L2

COMPRESSOR

RELAY

HEAT RELAY

FAN RELAY

1

2

R
Y

W

C

GL

GH

Typical 1H/1C 

Conventional 

System: 2 Speed Fan

1

2

3

4

Power supply
Jumper (not supplied) to connect GL and GH terminals

The Aux Heat Relay is energized as the second stage of heat.

Typical 1H/1C 

Conventional 

System: 1 Speed Fan

Thermostat changeover valve must be set to b on all

non-Heat Pump Systems.

7

Wiring Diagrams

Summary of Contents for 6041206

Page 1: ...NON PROGRAMMABLE WIRELESS THERMOSTAT 6041206 Installation and Operation Manual 6140429 Rev 08 24 20...

Page 2: ......

Page 3: ...e Yes Geothermal Yes Table of Contents page Installation Tips 2 3 Thermostat Quick Reference 4 Wiring 5 6 Wiring Diagrams 7 8 Technician Setup 9 10 Swing Setting 11 Specifications 12 Thermostat Applic...

Page 4: ...e of the building Do not install thermostat in locations Close to hot or cold air ducts That are in direct sunlight On an outside wall In areas that do not require conditioning Where there are dead sp...

Page 5: ...nstallation 1 5V AAA 1 5V AAA Battery installation is optional if thermostat is hardwired RH and C terminal connected to 24V power Important High quality alkaline batteries are recommended Rechargeabl...

Page 6: ...n indicator is shown 1 2 3 4 Press the or buttons to select the desired room temperature LCD 1 AUTO will turn the fan on only when the heating or cooling system is on Select LOW or HIGH for the fan to...

Page 7: ...s Terminal 1 Heat 1 Cool Conventional System 1 Heat 1 Cool Heat Pump System 2 Heat 1 Cool Heat Pump System R Transformer power Transformer power Transformer power C Transformer common Transformer comm...

Page 8: ...nnect the power before beginning to install this product can cause electrical shock or equipment damage Wire Specifications Use shielded or non shielded 18 22 gauge thermostat wire Warning All compone...

Page 9: ...2 R Y W C GL GH Typical 1H 1C Conventional System 2 Speed Fan 1 2 3 4 Power supply Jumper not supplied to connect GL and GH terminals The Aux Heat Relay is energized as the second stage of heat Typic...

Page 10: ...L GH Typical 1H 1C Heat Pump System 2 Speed Fan Typical 2H 1C Heat Pump System 2 Speed Fan 1 2 3 Power supply Cap o W Thermostat must be set to B on all Heat Pump Systems 2 Note Most PTAC systems supp...

Page 11: ...r systems that control the fan during a call for heat put the switch in the GAS position Technician Setup Menu 1 Set the thermostat system switch to OFF 2 To enter Tech Setup Menu press and hold and t...

Page 12: ...ill not allow the compressor to be turned on for 5 minutes after the last time the compressor was switched off Select OFF to remove this delay Change Over Value Selec tion Select 0 for a change over v...

Page 13: ...ing on at approximately 0 5 above the setpoint and turn the heating off at approximately 0 5 below the setpoint Swing Setting The second stage of heat will turn on at 2x the swing setting The second s...

Page 14: ...e or differential Heating is adjustable from 0 2 to 2 0 Cooling is adjustable from 0 2 to 2 0 Power Source 18 to 30 VAC NEC Class II 50 60 Hz for hardware Battery power from 2 AAA Alkaline batteries O...

Page 15: ...13 Specifications 3 86 1 1 1 2 375 4 72 3 00 1 75 1 125...