Electrical Ground: 

 

The HAG series generators are a low voltage output system (48volt, 
3ph, 240hz loaded).  As specified in the National Electrical Code 
(NEC) part 250.21 & 250.22 any “stand alone” low voltage system 
under 50 volts AC (loaded) does not require a ground.   
 
If an inspector on a specific job site “request” a grounded system, 
the HAG series units are equipped with a “ground lug” connection 
located on the side of the electrical control panel.  Simple attach a 
length of appropriate wire to the ground lug and attach to a ground 
connection as deemed acceptable to the inspector. 
 
Warranty  

 

 

 

 

 

 

 

 

 

 

 
ISKCO, Ltd. warrants to the purchaser that the equipment to be delivered herein will be free from 
defects in material, workmanship and title and will be of the kind and quality designated or described 
in the contract.  The foregoing warranty is exclusive and in lieu of all other warranties whether written 
or implied (including any warranty of merchantability or fitness for purpose).  If it appears within six 
(6) months from the date of shipment by the Company that the equipment delivered herein does not 
meet the warranties specified above and the purchaser notifies the Company promptly, the Company 
shall thereupon correct any defect, including non-conformance with the specifications, at its option, 
either by repairing any defective part of parts or by making available at the Company’s plant, a 
repaired or replacement part. 
 
In no event will ISKCO, Ltd. be liable for business interruptions, loss of profits, personal injury, cost 
of delay, or for any other special, indirect, incidental, or consequential losses, costs, or damages. 

 
 

Summary of Contents for HAG Series

Page 1: ..._____________ HAG Series Gen set Exclusive Power source for ISKCO 48 volt 3ph 240hz products _____________________ ISKCO Ltd N Little Rock AR 72113 Ph 501 812 0220 Fax 501 812 0770 www iskco com email vibration iskco com ...

Page 2: ... and the unit itself during high amperage situations Oil Alert Prevents the engine from operating when oil level is low 4 Cycle engine Durable clean burn engine for trouble free operation Caution Check oil level before starting engine NOTE Units are shipped containing no oil Do not run the generator in an enclosed area Failure to operate this generator in a ventilated environment can be hazardous ...

Page 3: ...generator OVL s as the on off device or slow down or shut off the generator without first turning off the vibrators at the vibrator switch Failure to do so can cause damage Generator Shutdown Use the following instructions when shutting the generator off 1 Turn the concrete vibrators OFF using the vibrator switch 2 Turn generator overload protector s to the OFF position 3 Return generator to idle ...

Page 4: ...orkmanship and title and will be of the kind and quality designated or described in the contract The foregoing warranty is exclusive and in lieu of all other warranties whether written or implied including any warranty of merchantability or fitness for purpose If it appears within six 6 months from the date of shipment by the Company that the equipment delivered herein does not meet the warranties...

Reviews: