Operation
For optimum performance and safety be sure to operate the generator according to the instructions
specified in this manual.
Check the oil level before operation!
(1)
Fill gas tank and open petcock to allow fuel to flow into the carburetor.
(2)
Adjust the throttle handle to the run position and move the choke to the closed position. (If re-
starting the generator while still warm, keep the choke in the open position).
(3)
Be sure the overload protectors are in the OFF position.
(4)
Pull recoil starter
(5)
Once the engine starts, gradually move the choke to the open position
(6)
Throttle the engine to
full speed.
(7)
Turn the overload protector(s) to the ON position before turning on the vibrators. NOTE: Start
vibrators one at a time to avoid overloading the generator.
(8)
Always turn vibrators “on / off” with the vibrator switch…do not use the generator OVL’s
as the on / off device or slow down or shut off the generator without first turning “off” the
vibrators at the vibrator switch. Failure to do so can cause damage.
Generator Shutdown
Use the following instructions when shutting the generator off.
(1)
Turn the concrete vibrators OFF using the vibrator switch
(2)
Turn generator overload protector(s) to the OFF position
(3)
Return generator to idle speed for approximately 2-3 minutes
(4)
Turn the engine switch off
(5)
Close the fuel petcock.
If storing the generator for a extended period time, turn fuel petcock off and allow engine to run until
shut down to insure fuel in not remaining in the carburetor bowl.
Generator maintenance
Clean the pins of the output receptacles with wire brush to insure maximum electrical performance.
Tighten all loose nuts and bolts.
Check exposed wiring for cuts or loose connections.
Engine maintenance
See the enclosed engine service manual for safety precautions and engine maintenance instructions.
Contact your local dealer to obtain more information.