3. Pull the fan straight up to remove the fan from the node.
Caution: Keep fingers clear of fan blades while removing the fan.
!
1
2
2 Fan alignment slot
1 Cooling fan
Figure 10. Removing a fan
4. Slide the new fan into the fan alignment slots with the arrow on top of the fan pointing toward the rear of the node.
5. Press the fan straight down to secure the fan.
The fan should begin spinning and the fan fault LED should turn off.
6. Replace the node top panel.
For more information, see
on page 39.
7. Return the old hardware to Isilon Technical Support.
For more information, see
on page 6.
20
©
2011 Isilon Systems, LLC.
Cooling fans