User Reference Manual - DuraMON
PN: 05192-075 Rev B Page 27
ECDIS mode
16
Be aware that use of the backlight, brightness or contrast controls in ECDIS mode may inhibit
visibility of information particularly at night!
To setup ECDIS on the system a color map must be downloaded from the monitor to the ECDIS
application. Please see the Dura Serial Communication protocol for details.
Dura Serial Communication protocol
17
See document 04924-001 for protocol details.
The t
ype of the product can be queried by sending the ‘TYP’ command, ref. the Serial Protocol
Document.
Monitor
Typ response from monitor
DuraMON 15
DuraMON 15
DuraMON 19
DuraMON 19
DuraMON 22
DuraMON 22
DuraMON 24
DuraMON 24
DuraMON 26
DuraMON 26
DuraMON 27
DuraMON 27
Compass safe distance
18
Test object / condition
Minimum Compass safe
distance [cm]
(5.4°/H deviation or a
horizontal magnetic flux of
0.094µT)
Minimum Compass safe
distance [cm]
(18°/H deviation or a horizontal
magnetic flux of 0.313µT)
DuraMON 15
165
115
DuraMON 19
65
35
DuraMON 22
175
110
DuraMON 24
215
140
DuraMON 26
225
135
DuraMON 27
180
110