2.8 TROUBLE SHOOTING
PROBLEM SOLUTION
Cannot enter a tare weight through the
keyboard.
Tare weight must end in the smallest division of scale
weight.
After turning on the scale there are no
displays and no beeps.
•
Check scale is plugged in to a live outlet.
•
Unplug scale from outlet and check main fuse.
After turning on the scale there are no
displays but buzzer sounds continuously.
•
Check the weigh platter is mounted on scale correctly.
•
Check that no objects are touching the weigh platter
from above, side, or below.
•
Scale is out of calibration due to overload or shock
load-contact service representative.
Reading weight is unstable.
•
Check that no objects are touching the weigh platter
from above, side, or below.
•
Check that scale is level.
•
Check for air currents, vibration, or unstable mounting
surface.
INS-100 Operator’s Manual No. IW05XINS100-A