17 - 23
2-4 Installation
2-4.1 Positioning and mounting
The lubrication unit is attached to the
intended mounting location (3) using
appropriate fastening materials (1).The
mounting dimensions of fixing holes for 2L
are measured between 172 to 180mm ; 3L
between 190 to 205mm ; 4L between 230 to
250mm. The installation location should be
spaced between 0.6m to 1.7m above the
ground
(Fig.2)
2-4.2 Filling oil
Remove the oil tank cap and fill clean and
non-used oil into the tank and add up to the
HIGH mark (Fig. 3). Please note that only use
permitted range of oil viscosity between
30cSt to 250cSt.
Warning!
Motor jammed or burned due to
high resistance which caused by delivering
higher than an oil viscosity of 250cSt.
(Fig.3)
2-4.3 Lubrication line connection
Solderless tube connection (double tapered
sleeves) can be used. The tube must go
through compressed bushing and double
tapered sleeve (See Fig. 4). To avoid any
leaking during running service time, it should
be observed up to 1mmdistance between the
tube end to the double sleeve.Insert tube end
into counter bored port (3) up to the stop.First
tighten compressed bushing finger-tight by
hand. Then turn another 1
1
/
2
turns.
(Fig.4)