17 - 23
2-4 Installation
2-4.1
Positioning and mounting
The lubrication unit is attached to the intended
mounting location (3) using appropriate fastening
materials (1).The mounting dimensions of fixing
holes for 2L are measured between 172 to 180mm ;
3L between 190 to 205mm ; 4L between 230 to
250mm. The installation location should be spaced
between 0.6m to 1.7m above the ground.
(Fig.2)
2-4.2
Filling Oil
Remove the oil tank cap and fill clean and
non-used oil into the tank and add up to the HIGH
mark (Fig. 3). Please note that only use permitted
range of oil viscosity between 30cSt to 250cSt.
Warning!
Motor jammed or burned due to high
resistance which caused by delivering higher than
an oil viscosity of 250cSt.
(Fig.3)
2-4.3 Lubrication line connection
Solderless tube connection (double tapered sleeves)
can be used. The tube must go through compressed
bushing and double tapered sleeve (See Fig. 4). To
avoid any leaking during running service time, it
should be observed up to 1mmdistance between the
tube end to the double sleeve.Insert tube end into
counter bored port (3) up to the stop.First tighten
compressed bushing finger-tight by hand. Then turn
another 1
1
/
2
turns.
(Fig.4)