17
-
20
Fig. 6
Fig. 7
Fig. 8
3. General information
3-1
Set up output volume
Loosen Frank nut (1) and turn the regulating plate (2) to the required output volume
listed on the technical data. Then tight Frank nut on the regulating plate.
Fig.9
3-2 Refilling lubricant
Always keep the oil level between HIGH mark and LOW mark. If the oil level falls
below LOW mark, the lubrication unit of YESB will send an alarm signal to the control
unit of the machine. For YESA model, it doesn’t contain level switch and the user has to