background image

Credential reader

User Manual

EN 02

STYLOS

Summary of Contents for STYLOS

Page 1: ...Credential reader User Manual EN 02 STYLOS ...

Page 2: ......

Page 3: ...f Stylos the ISEO credential reader For commercial documents catalogues and leaflets technical documents installation and maintenance manuals and certifications refers to the ISEO website at the following link https www iseo com Information icons For an easy reading of the manual please take note of the following icons CAUTION situations that could cause damage to your Device or other equipment NO...

Page 4: ...Access control device electronic and or mechanical device to allow selective access through the users door Contactless card electronic card that can be read by the Access control device by simply bringing it closer to the same without physical contact Credential device that allows to identify the user and authorize or not authorize access through a door For example smartphone tablets Mifare cards ...

Page 5: ...ing Stylos 20 Programming and using Stylos Installation examples 21 Introduction 22 Stylos opening Multiblindo eMotion 23 Stylos opening Serie 5 electric lock 24 Stylos opening Trim Tronic 25 Stylos opening ISEO Automatic Swing Door Operator IS9100 26 Stylos opening Thesis 2 0 27 Two Stylos opening an electric strike Cable sizing 28 Lockbus technical data 29 Lockbus and power supply unit sizing ca...

Page 6: ...d in these instructions The product must be destined only for the use for which it is expressly designed and therefore as a credential reader for civil and industrial locations Any other use is considered improper and dangerous The electrical connection must be made according to the constructor s instructions and respecting the regulations in force In the event of a failure and or poor operation r...

Page 7: ...e Risk of explosion if the battery is replaced by an incorrect type Use only battery of the same type as indicated in the product installation guide Do not open drill through or squash lithium batteries Do not expose the battery to flame or to excessive heat Do not immerse in or expose to water Do not short circuit lithium batteries Do not recharge lithium batteries Do not connect lithium batterie...

Page 8: ...es in charge of waste management This symbol on the battery indicates that the battery is to be collected separately Dispose of batteries according to your local environmental laws and guidelines This symbol indicates to not dispose of the packaging with household waste but send it for recycling Dispose of the product separately from household waste in accordance with local laws and regulations Re...

Page 9: ...ur mobile device is a radio transmitter and receiver It is designed not to exceed the limits for exposure to radio waves radio frequency electromagnetic fields recommended by international guidelines RFID tag reader BTLE Frequency type Frequency band MAX emission value 13 553 13 567 MHz Maximum magnetic field 0 89 µA m at 10m 2 40 2 4835 GHz Maximum power 5 25 mW BTLE only on models with radio com...

Page 10: ...light commercial offices single entrance of commercial server rooms etc For the installation of Argo app device initialization setup of the opening and other operations not described herein refer to the Argo User Manual available at iseo com Signallling LED LCD Display RFID reading area RFID reading area Keypad Stylos take also advatanges of the next importants and uniques features Real Time Clock...

Page 11: ... Stylos Smart Software upgrade on site 10 years of average duration 8Vdc to 30Vdc 3W LEDs 3 color series green red and blue Graphic display O led 128x64 dots Signallling LED version Signallling Display version 3 wires multipoint serial bus for power and data Connection up to 100 mt Self adjusting power supply from 8Vdc to 30Vdc Secure device authentication among readers and actuators and encrypted...

Page 12: ...l or analogic Inputs by electronic actuator Outputs by electronic actuator 1 relay 24V 1A 1 booster for direct electric lock Feature Characteristics Power supply 8Vdc to 30Vdc Storage temperature 25 C 75 C Operating temperature 0 C 60 C Environmental characteristics Protection system IP grading IP54 Electric Lock Actuator Power consumption 3W 3 wires multipoint serial bus for power and data Connec...

Page 13: ...13 Overview Dimensions A 47 50 B 17 50 C 130 Dimensions mm C A B ...

Page 14: ...ied in different version Stylos LED Stylos Display with keyboard and Stylos All Weather only LED version For more detailed information go to the on line catalogue at iseo com website 1 Stylos LED 2 Stylos Display with keyboard LED Display Numeric keypad ...

Page 15: ... connect the Credential reader to the Control Unit 5mt is the maximum allowed distance between the 2 modules The module encloses the RFID contactless multi standard reader completeley sealed for outdoors installation to resist against rain snow and humi dity exposure IP66 This module encloses the Stylos electronic board with Bluetooth 4 0 and Lockbus communication interface It needs to be installe...

Page 16: ...n about Stylos and Stylos All Weather installation refer to the Installation Guides available at iseo com Stylos All Weather installation scheme Credential reader Connection cable max 5mt lenght Control unit OUTDOOR SIDE INDOOR SIDE ...

Page 17: ... relay of any other access control device such as car park bars sliding do ors electric locks and many more Controlled by Stylos allows to open any electrical device Lockbus interface DIN35 rail housing Electric Lock Actuator dimensions For more information about the Electric Lock Actuator installation read to the Installation Guides or the catalogue available at iseo com ...

Page 18: ...nes For all the power supply codes refer to the catalogues available at iseo com Graphic Description Features Power supply unit 24Vdc 30W Power supply unit 24Vdc 70W Input 120 230Vac Output 24Vdc 1 2A DIN35 rail mounting Input 120 230Vac Output 24Vdc 3A DIN35 rail mounting B Plastic back housing for wall installation Specifically designed for mounting with external electrical conduit or to avoid d...

Page 19: ...ylos 2 screws for metal 2 screws for plastic 2 washers 2 fisher adaptors Installation guide The items supplied with the Device and any available accessories may vary depending on the region or service provider Appearances and specifications are subjected to change without prior notice ...

Page 20: ...illed technical staff following the Stylos Installation Guide available at iseo com For a correct procedure see also Warnings at the Safety and Environment chapter For these operations please refer to Argo User Manual for Stylos Smart or V364 System Administra tor Manual for Stylos Both available at iseo com ...

Page 21: ... max cross section of the cables is 0 20 1 5 mm 24 15AWG Power supply 8 30 Vdc 3W Min max cross section of the cables is 24 15AWG for terminals J2 J3 and 24 13AWG for terminal J1 Power supply 12 Vdc 2A 30W Wires minimum cross section 0 35mm to 2 5mm depending on cable distance To power up Stylos Actuator and MB eMotion Input 120 230 Vac Output 12 Vdc 3 40W To connect the devices See Cable sizing p...

Page 22: ... the device s box or available at iseo com Stylos opening Multiblindo eMotion Lockbus In this example to simplify the scheme it has been used a single power supply to power all devices On real plants scenario for service and maintanance purpose it is usually recommended to sepa rate Stylos and Actuator power supply from the electrical device in this case Multiblindo eMotion by using 2 different po...

Page 23: ...ction and power supply sizing go to Cable sizing paragraph For more technical information about wiring and connections refer to the device s installation guides included in the device s box or available at iseo com Stylos opening Serie 5 electric lock Lockbus 12VDC 3A ...

Page 24: ...ss section and power supply sizing go to Cable sizing paragraph For more technical information about wiring and connections refer to the device s installation guides included in the device s box or available at iseo com Stylos opening Trim Tronic Lockbus 12VDC 3A ...

Page 25: ...power supply sizing go to Cable sizing paragraph For more technical information about wiring and connections refer to the device s installation guides included in the device s box or available at iseo com Stylos opening ISEO Automatic Swing Door Operator IS9100 Lockbus 12VDC 3A ...

Page 26: ...chnical information about wiring and connections refer to the device s installation guides included in the device s box or available at iseo com Stylos opening Thesis 2 0 Thesis 2 0 embeds the Lockbus communication interface therefore it can be connected directly to Stylos without the need of the Electric Lock Actuator Lockbus 12VDC 3A ...

Page 27: ...n and power supply sizing go to Cable sizing paragraph For more technical information about wiring and connections refer to the device s installation guides included in the device s box or available at iseo com 2 Stylos opening an electric strike Lockbus Lockbus 12VDC 3A ...

Page 28: ...ortant to properly dimension the Lockbus power supply unit Distance between all devices connected on the same Lockbus line Total Lockbus channel cable length sum of all branches must not exceed 100mt Lockbus power suppy unit voltage and power Cable voltage drop due to distance wires size and type of power supply Lockbus technical data 60 pF mt Recommended cable capacitance Maximum lockbus length s...

Page 29: ...tion mm2 22 20 18 17 15 13 0 35 0 5 0 75 1 1 5 2 5 From 0 to 5 From 5 to 10 From 10 to 40 From 40 to 50 From 50 to 75 From 75 to 100 Lockbus and power supply unit sizing calculation example Referring to the previous installation example Stylos opening Multiblindo eMotion let s properly size the Lockbus cable and the power supply unit Lockbus 12VDC 3A ...

Page 30: ... in the following table Electric Lock Actuator Multiblindo eMotion Device Specifications Stylos Power supply 8 30 Vdc 0 5A Power consumption 3 W Indoor version IP54 Placed outside the house on the wall in a covered place next to the main entrance equipped with Multiblindo eMotion Lockbus communication protocol Power supply 8 30 Vdc 0 5A Power consumption 3 W Placed inside the house in a box nearby...

Page 31: ...this battery is not used The average lithium cell battery life is about 10 years If you need to replace this battery follow the next procedure To prevent damage to the equipment and risk for the users battery replacement must be carried out by a specialized technician Battery replacement does not affect the data stored in the User List 1 Remove the Stylos fom the wall 1 2 3 4 ...

Page 32: ...32 Maintenance 2 Disconnect the Stylos connector plug 3 Remove the ESD protection 3V LITHIUM CR2032 3V LITHIU M C R2 032 3V LITHIUM CR2032 Back view Circuit side Back view Circuit side ...

Page 33: ...he electronic board Then install the new ones 3V LITHIUM CR2032 The battery has to be collected separately Dispose of batteries according to your local environmental laws and guidelines 3V LITHIUM CR2032 If the battery is disconnected for more than 5 minute the Device clock might go out of synchronization To synch the clock Stylos Smart enter Programming Mode with Master Card and the door lock wil...

Page 34: ... as alcohol thinners benzene acidic or alkaline solvent cleaners abrasive cleaners or lubricants as these may damage the device s finish and cause discoloration For not installed product store Stylos in a clean dry place at a room temperature between 25 C and 75 C and relative humidity between 20 and 95 For a better storage use the original packing box Cleaning Storage Maintenance Before performin...

Page 35: ...connection on lockbus connectors Faulty electronic unit Solution Replace the Stylos Check wires connections on Card reader and Control unit Faulty electronic unit Faulty electrical connections Only All Weather version Check or replace appliance Check appliance power supply if present Replace Actuator Check Actuator power supply if present Replace Control unit Faulty appliance Faulty appliance powe...

Page 36: ...ble at iseo com For any help please contact ISEOZero1 Technical Support Visit iseo com website to find your country telephone number When you contact the ISEOZero1 Technical Support please provide the next information Device Model Date of purchase Software version Precise description of the problem Light and acoustic signals Technical assistance ...

Page 37: ...37 Notes ...

Page 38: ... GmbH zero1 de iseo com GERMANY Iseo Projects and Access Control DMCC iseoprojects iseo com 971 4 5136162 UNITED ARAB EMIRATES ISEO South Africa Pty LTD zero1 za iseo com SOUTH AFRICA ISEO Beijing zero1 cn iseo com 8610 58698079 ASIA ISEO Asia Pacific SDN BHD zero1 asia iseo com 603 80753331 Feroneria Prod S A zero1 ro iseo com ROMANIA www iseo com Iseo Serrature s p a Via San Girolamo 13 25055 Pi...