Turned tool changing station SK11 and SK20
26
/
27
April 2019
7
Faults
Fault
Measures
Tool flap does not move
1
– Check pneumatic connection
2
– Check voltage supply
3
– Check communication
Tool does not move to
OUT or IN
1
– Check pneumatic connection
2
– Check voltage supply
3
– Check communication
Motor does not turn
1
– Check voltage supply
2
– Confirm with “ACK button” with system in test mode
3
– Unlock 'Emergency STOP'
4
– Eliminate error in safety circuit
5
– Check communication
The magazine remains in
an incorrect position
1
– Re-teach tool slots
2
– Check step resolution
No communication
1 – Check COM port
8
Disposal
Return of waste electrical and electronic devices for disposal
Collection
Users of electrical and electronic devices are obligated, in accordance with the country-specific
regulations, to separate disposal of the waste equipment. Waste electrical and electronic equipment
may not be disposed of with household waste. The separate collection required for recycling and re-
use, whereby natural resources can be conserved.
Return and collection systems
Disposal of your SK11 and SK20 turned tool changing station, particularly the electronic components,
may not take place with household waste. Local waste disposal companies have made the necessary
disposal facilities available for this purpose.
Meaning of symbols
All electrical and electronic equipment identified with this symbol must not be disposed of with
household waste in accordance with EU Directives.