3.3 Operation states
The device is remote controlled via the analogue interface. Figure 2: Operating area of the device shows the operating area of the
device. There are two modes for high voltage generation:
1.
Constant voltage control CV:
Regulation of the output voltage according to the set value of the output voltage under the condition measured output
current (I
MON
) < set value output current (I
SET
).
2.
Constant current control CC:
Regulation of the output current according to the set value of the output current under the condition measured output
voltage (V
MON
) < set value output voltage (V
SET
).
Figure 2: Operating area of the device