Summary of Contents for ECH 124

Page 1: ... ECH 124 128 12A 14A MMC Crate Series for iseg MMC High Voltage Power Supply Modules up to 10 MMC High Voltage Power Supply Modules 150 300 480 W power supply wide range of HV modules CPS DPS EPS series for the use with MICC controller www iseg hv com ...

Page 2: ...f publication without a written permission of iseg Spezialelektronik GmbH This information has been prepared for assisting operation and maintenance personnel to enable efficient use The information in this manual is subject to change without notice We take no responsibility for any mistake in the document We reserve the right to make changes in the product design without reservation and without n...

Page 3: ...afety instructions DANGER DANGER Danger indicates a severe injury hazard The non observance of safety instructions marked as Danger will lead to possible injury or death WARNING WARNING Warning indicates an injury hazard The non observance of safety instructions marked as Warning could lead to possible injury or death CAUTION CAUTION Advices marked as Caution describe actions to avoid possible dam...

Page 4: ...s on the basis of his technical training his knowledge and experience as well as his knowledge of the relevant regulations General safety instructions Observe the valid regulations for accident prevention and environmental protection Observe the safety regulations of the country in which the product is used Observe the technical data and environmental conditions specified in the product documentat...

Page 5: ...lowed to open the unit There are no parts which can be maintained by users inside of the unit Opening the unit will void the warranty WARNING WARNING Before connecting or disconnecting HV cables or any operation on the HV output or the application the unit has to be switched off and discharge of residual voltage has to be finished Depending on application residual voltages can be present for long ...

Page 6: ... of the unit WARNING WARNING The mains connection is made with basic insulation and protective conductor The device may only be operated with the protective earth conductor PE connected The protective conductor connections must be checked for proper function after installation CAUTION CAUTION When installing the units make sure that an air flow through the corresponding air inlet and outlet openin...

Page 7: ...kage contents Accessories 8 3 Technical data 9 4 Order options 10 5 Operation and maintenance 11 6 Configuration of the HV Modules slot position 11 7 Compatibility lists 11 8 Dimensional drawings 12 9 Connectors and PIN assignments 16 10 Accesories 17 11 Order guides 18 12 Appendix 18 13 Glossary 19 14 Warranty Service 20 15 Disposal 20 16 Manufacturer contact 20 ECH 124 128 12A 14A MMC Crate Last...

Page 8: ...work communcation of the MMC modules the iseg MICC crate controller needs to be plugged into the special Controller Slot The MICC connects the analog interfaces of the MMC HV devices in a 3U Euro cassette with digital standard interfaces This allows devices with analog I O to be integrated into digitally controlled systems The high resolution of the analog inputs and outputs allows very precise co...

Page 9: ... 150 W 150 W Connection CAN USB 1 Ethernet 1 Interfaces 1 16 x 20 bit analog OUT 32 x 24bit analog IN 24 digital I O Inhibit Lemo hub on the rear connected with INHIBIT signal from all HV modules TTL level LOW active VOUT 0 Volt see also Connectors and PIN assignments Operation temperature 0 C 50 C Storage temperature 20 C 70 C Dimensions L W H 315 mm 249 mm 3U 308 mm 19 3U Weight 3 4 kg 4 5 kg No...

Page 10: ... LOW active VOUT 0 Volt see also 9 Connectors and PIN assignments Operation temperature 0 C 50 C Storage temperature 20 C 70 C Dimensions L W H 308 mm 19 mm 3U 308 mm 19 3U Weight 4 1 kg 4 1 kg 4 6 kg 2 Notes 1 Requires the use of MICC controller not included in ECH delivery 2 For ECH 14A with 480W power supply 3 The ECH 14A is configured for the operation with the installed modules A modification...

Page 11: ... crate the controller will start up in standby mode For more details and handling please read the corresponding manual 6 Configuration of the HV Modules slot position The slot positions of the HV modules in the crate is preconfigured by the factory This configuration has to be stored in the firmware of the controller board and may be changed through a hardware switch on the backplane If its necess...

Page 12: ...8 Dimensional drawings Figure 1 ECH 124 with MICC controller ECH 124 128 12A 14A MMC Crate Last modified on 24 01 2020 www iseg hv com 12 20 ...

Page 13: ...Figure 2 ECH128 with MICC controller ECH 124 128 12A 14A MMC Crate Last modified on 24 01 2020 www iseg hv com 13 20 ...

Page 14: ...Figure 3 ECH12A with MICC controller ECH 124 128 12A 14A MMC Crate Last modified on 24 01 2020 www iseg hv com 14 20 ...

Page 15: ...Figure 4 ECH14A with MICC controller ECH 124 128 12A 14A MMC Crate Last modified on 24 01 2020 www iseg hv com 15 20 ...

Page 16: ...IGH or n c HV OFF 18 2 VIN Vin Supply voltage 24 V DC 20 VSET Vset Set value of output voltage 0 5 V 22 POL Polarity HIGH or n c positive LOW negative 24 VMON Vmon Monitor voltage 0 5 V 26 VIN Vin Supply voltage 24 V DC 28 ISET 1 Iset Set voltage of output current 0 5 V 30 KILL_ENA Killenable high active TTL level 32 INH Inhibit LOW active shut down the output voltage TTL level LOW HV OFF HIGH or ...

Page 17: ... Only use genuine iseg parts like power cables CAN cables and terminators for stable and safe operation ACCESSORY ITEM ORDER ITEM CODE CANbus Adapter RJ45 to SUB D 9 male Z583382 CANbus Adapter RJ45 to SUB D 9 female Z583401 Genuine power cable EU Plug Z592069 Front panel blind RAL9001 3U 4HP Z515662 Front panel blind RAL9001 3U 8HP Z580789 CANbus terminating resistor Sub D 9 male Z510245 1 pin LE...

Page 18: ... Table 9 Configuration item code 12 Appendix For more information please use the following download links This document https iseg hv com download SYSTEMS MMC ECH iseg_manual_ECH12x 14x_en pdf Crate Controller MICC https iseg hv com de products detail MMC Controller CPS Series https iseg hv com en products detail CPS DPS Series https iseg hv com en products detail DPS EPS Series https iseg hv com ...

Page 19: ...t Vbounds around Vset Inom nominal output current Iout output current Iset set value of output current Imon monitor voltage of output current Imeas digital measured value of current Itrip current limit to shut down the output voltage Iin input supply current Imax limit max value of output current Ilimit Current Limit Ibounds Current bounds a tolerance tube Iset Ibounds around Iset Pnom nominal out...

Page 20: ...pport rma 15 Disposal INFORMATION INFORMATION All high voltage equipment and integrated components are largely made of recyclable materials Do not dispose the device with regular residual waste Please use the recycling and disposal facilities for electrical and electronic equipment available in your country 16 Manufacturer contact iseg Spezialelektronik GmbH Bautzner Landstr 23 01454 Radeberg OT R...

Reviews: