4.6
Heating the needle probe
Pressing this area enables selection of a needle
probe, or probes, heating cycle.
This cycle can also be run automatically if the
key is
pressed during conservation, following a blast chilling/defrosting
cycle.
The function can be activated by parameter and can only be used
if u1=2 or u3=1. If cabinet sterilisation has also been enabled, the
needle probe heating icon is shown if the temperature recorded by
the needle probe is above 0°C .
The needle probe heating output is activated at maximum for the
time set by parameter u8 or until the temperature indicated by the
needle probe has reached that set by parameter u7.
At the end of heating, the buzzer sounds.
Heating can be stopped by pressing the
key.
4.7
Drying
Pressing this area enables selection of a drying
cycle.
This is a cycle of forced-air ventilation that can be activated with
the door closed and for a duration set by parameter u13. If the
door is opened during drying this does not affect the cycle.
The cycle stops when the prescribed time has elapsed or when the
key is pressed.
Summary of Contents for ZERO TOUCH T12
Page 26: ...26 EN 428000729137 USE AND MAINTENANCE MANUAL ZERO TOUCH 11 1 CONTAINERS ARRANGEMENT...
Page 27: ...EN USE AND MAINTENANCE MANUAL 428000729137 27 ZERO TOUCH 11 2 KIT SUPPORTS ICE CREAM T5 T8...
Page 28: ...28 EN 428000729137 USE AND MAINTENANCE MANUAL ZERO TOUCH 11 2 KIT SUPPORTS ICE CREAM T12...
Page 29: ...EN USE AND MAINTENANCE MANUAL 428000729137 29 ZERO TOUCH 11 2 KIT SUPPORTS ICE CREAM T16...
Page 39: ......
Page 40: ...ISA Bastia Umbra Perugia Italy Tel 39 075 80171 Fax 39 075 8000900 www isaitaly com...
Page 71: ......
Page 72: ...ISA Bastia Umbra Perugia Italy Tel 39 075 80171 Fax 39 075 8000900 www isaitaly com...