41
MILLENNIUM
EN 428001275137
Use and maintenance manual
4
Remove the condensing unit as shown.
Clean the condensing unit using a dedicated soft bristle brush
and a vacuum cleaner; carry out the operation taking care not to
bend the condensing unit springs.
18.3
FILTER
Manually extract the filter as indicated.
Vacuum dust from the filter.
Wash with running water and wait
for it dry completely before reassembling it.
A
B