14
MILLENNIUM
EN 428001275137
Use and maintenance manual
8.
MAINTENANCE
The
Staff in charge of the appliance
must control and respect the expiry dates for maintenance, given in the table below,
contacting the authorised
Technical Assistance
when indicated.
ATTENTION
After any maintenance it is
mandatory
to perform the electric safety tests in compliance with the IEC EN 50106
Standard.
FREQUENCY
Maintenance
Manager
Accor
ding to Use
and Requir
ement
Monthly
Every 6 months
Annual
Cleaning the external surfaces
USER
Cleaning of accessible internal parts.
(without the use of tools)
Check integrity of sealing gaskets.
Control of power supply cable/plugs and/or electrical sockets.
Cleaning the condenser unit filter.
(If present)
Cleaning the defrosting water collection tray.
TECHNICAL ASSIST
ANCE
Cleaning the water collection tank.
(Inside the tank - if present)
Condenser cleaning.
Control of oil level of compressor.
(Where present)
Drainage discharge of air tank.
(Where present)
Control of pneumatic connections.
(Where present)
Check the integrity of chiller system piping.
Inspect cables and internal power connections.
Cleaning of the condensation dryer sponges.
(Where present)
Replacement of lights / LEDs.
(Where present)
Replacement of control panel.
(Electronic control unit - thermostat - etc.)
Replacing the power supply cable, plugs and/or electric sockets.
(If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard)
Ordinary Maintenance