iSC2 User
’s Manual
iS5 Communications Inc.
10
Position
State
Notes
1
ON
RS232 to fiber
2
OFF
RS232-to-RS485/422 conversion
3
ON/OFF
Full-duplex (485-4W or 485-2w)
4
OFF
No 120 Ohm termination
5
OFF
Fiber repeater
Note: Position 3 is applied to RS485 only
RS422/RS485 Device
Position
State
Notes
1
OFF
RS232 to fiber
2
OFF
RS232-to-RS485/422 conversion
3
ON
Full-duplex
4
OFF
No 120 Ohm termination
5
OFF
Fiber repeater
In this mode serial data is converted directly into light signal, and transmitted over multi-mode fiber
optics. The serial standard is selected by position 1 of the DIP switches: OFF (default) is for
RS485/RS422, and ON is for RS232. Position 2 should be OFF for serial to fiber conversion. Position
6-10 should be configured if RS485 communications are used, in order to have the appropriate turn-
around timer shown below selected. Positions 6-10 do not impact communications in full-duplex mode.
Baud Rate (bps)
DIP6
DIP7
DIP8
DIP9
DIP10
1200
– 2400
ON
OFF
OFF
OFF
OFF
4800
– 9600
OFF
ON
OFF
OFF
OFF
14400
– 19200
OFF
OFF
ON
OFF
OFF
28800
– 38400
OFF
OFF
OFF
ON
OFF
57600
– 115200
OFF
OFF
OFF
OFF
ON