![IS5 COMMUNICATIONS iDS6 Series User Manual Download Page 24](http://html1.mh-extra.com/html/is5-communications/ids6-series/ids6-series_user-manual_2092162024.webp)
iDS6
Series User’s Manual
iS5 Communications Inc.
24
Serial Configuration interface
The following table describes the Serial Configuration interface page.
Label
Description
Port
Select a port (1-4) to see the settings.
Port Alias
Each port can be given a name (Defaults are: Port1, Port2, Port3,
Port4). This allows the port to indicate the connected device.
Interface
Select the interface (RS232, RS422, RS485 2 wire, or RS485 4 wire).
The default is RS232.
Baud Rate
The Baud rate can be set to: 110, 300, 1200, 2400, 4800, 9600,
19200, 38400, 57600, 115200, 230400, or 460800 bps. The default is
38400 bps.
Data Bits
Data Bits can be set to: 5, 6, 7, or 8. The default is 8.
Stop Bits
Stop Bits can be set to: 1 or 2(1.5). The default is 1.
Parity
Parity can be set to: None, Odd, Even, Mark, or Space. The default is
None.
Flow Control
Flow control can be set to: None, XON/XOFF, RTS/CTS, DTR/DSR. The
default is None
Force TX Interval
Time
Force TX interval time is to specify the timeout when no data has
been transmitted. When the timeout is reached or the TX buffer is
full (4K Bytes), the queued data will be sent. When set to 0, this
function is disabled. Factory default value is 0.
Performance
Select one of the two Performance Modes:
Throughput
provides optimization for highest transmission speed.
Latency
provides optimization for shortest response time.
Apply
Click “
Apply
” to activate the configurations.