background image

         1

10003929

10003929

01/02   Rev. 0

*   Installation and service must be

performed by a qualified installer,
service agency or your gas supplier.

DO NOT STORE

OR USE GASOLINE OR OTHER

FLAMMABLE VAPOURS AND LIQUIDS

IN THE VICINITY OF THIS OR ANY

OTHER APPLIANCE.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS:

* Do not try to light any appliance.
* Do not touch any electric switch.
* Do not use any phone in your building.
* Immediately call your gas supplier

from your neighbours phone. Follow
the gas suppliers instructions.

* If you cannot reach your gas supplier

call the fire department.

WARNING! IF THE INFORMATION IN

THIS MANUAL IS NOT FOLLOWED

EXACTLY, A FIRE OR

EXPLOSION MAY RESULT CAUSING

PROPERTY DAMAGE,PERSONAL

INJURY OR LOSS OF LIFE.

Installation Instructions &

Homeowner's Manual

DIRECT VENT

INSERT

MODEL

IRHEDV32

INSTALLER:  DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER

Summary of Contents for IRHEDV32

Page 1: ...liance Do not touch any electric switch Donotuseanyphoneinyourbuilding Immediately call your gas supplier from your neighbours phone Follow the gas suppliers instructions If you cannot reach your gas...

Page 2: ...nting and Installation 6 Liner Installation 7 Venting Diagram 7 Fan Kit 8 Fan Removal Instructions 8 Operating Instructions 9 General Glass Information 9 Louvre Removal 9 Glass Cleaning 9 Glass Frame...

Page 3: ...om as your appliance 4 Under no circumstances should this appliance be modified Parts removed for servicing should be replaced prior to operating this appliance again 5 Installation and any repairs to...

Page 4: ...rim 3 SXL Trim 4 BSL Trim 5 BXL Trim T R I M F I R E P L A C E M I N I M U M O P E N I N G IRHEDV32 A1 265 8 676 mm B1 383 8 975 mm A2 29 737 mm B2 4115 16 1065 mm A3 33 838 mm B3 44 1118 mm A4 28 712...

Page 5: ...SI Z223 1 Always check for gas leaks with a mild soap and water solution Do not use an open flame for leak testing 1 2 GAS SUPPLY 1 2 X 3 8 REDUCER 3 8 NIPPLE 3 8 NIPPLE 3 8 NIPPLE 3 8 X 3 8 SHUT OFF...

Page 6: ...cordance with the National Provincial State and local building codes and is constructed of non combustible materials 2 Only HEDVT 8 x 12 or HEDVT 12 x 12 termination kit and flex vent kit HEDVK25 or H...

Page 7: ...ation Feed one 3 flex vent from the bottom of the termination up through the 4 sleeve Apply hi temp sealant on the rain cap collar and slide the flex vent over the end of the rain cap collar fastening...

Page 8: ...OL B TEMPERATURE SENSOR C FAN Fig 12 115 volt 60 Hz 56W The fan kit includes the following fan temperature sensor speed control and a 6 ft cord The following explains how to start and set the fan for...

Page 9: ...that the glass be cleaned two or three times with a non ammonia household cleaner and warm water we recommend gas fireplace glass cleaner After that the glass should be cleaned two or three times dur...

Page 10: ...clean This must be done periodically at least once per season See Cleaning Procedure b Clean the brass trim using a soft clean cloth slightly dampened with lemon oil and buff with a soft clean cloth D...

Page 11: ...f the gas control Fig 18 It is important to periodically perform a visual check of the pilot and the burner flames Compare them to the pictorials illustrated below Fig 19 and 20 If any of the flames a...

Page 12: ...r Rn RP appliances turn the On Off switch to On positin or set thermostat to desired setting 14 Turn on all electrical power to the fireplace If you cannot reach your gas supplier call the Fire Depart...

Page 13: ...tch ON replace defective wall switch If okay jumper wires across wall switch wires at valve if burner comes on wires are faulty or connections are bad B Thermopile may not be 1 Be sure wire connection...

Page 14: ...5mV ADJUST PILOT FLAME HEIGHT ALL WIRING CONNECTIONS REPLACE THERMOPILE THERMOCOUPLE NEEDS A MINIMUM OF 14mV DEFECTIVE VALVE TURN TO PILOT METER SHOULD READ GREATER THAN 100 mV IF NOT REPLACE PILOT LI...

Page 15: ...15 10003929 REPLACEMENT PARTS IRHEDV32 35 30 31 32 27 29 28 25 26 3 2 33 34 22 24 15 L O H I PILOT ADJ P I L O T ON OFF 23 a b 21 20 19 14 12 16 8 a b 9 a b 13 18 17 11 a b 18 10a b...

Page 16: ...0a Pilot Assembly SIT Nat 10000674 10b Pilot Assemby SIT Prop 10000675 11a Pilot Assembly PSE Nat 10001741 11b Pilot Assembly PSE Prop 10001742 12 Pilot SIT 10001295 13 Pilot w ignitor and cable PSE 1...

Page 17: ...cing 3 Place the trim facing inner top in place do not fasten it yet Peel off the plastic protective covering from the bottom edge 4 Install the trim top deflector and fasten it will hold the inner to...

Page 18: ...st the front of the frame in order to prevent screws from damaging glass edges Fig 25 AS SHOWN FROM FRONT SCREWS FRAME MOUNTING GENERAL INFORMATION The Decorative Front Frame should be installed last...

Page 19: ...g Inner Left 1 17620 17619 9 Trim Facing Inner Right 1 17622 17621 10 Fasteners Package Not Shown 55043 55043 55043 55043 55043 TRIM REPLACEMENT PARTS LIST 1 Specify Finish Antique or Polished Brass 2...

Page 20: ...the bottom of the top channel Use the nuts supplied with the kit 5 Reinstall the two screws to hold the top trim channel RHEBXL A2 RHEBSL RHEBXL TRIMS KEY DESCRIPTION RHEBSLP RHEBSLA RHEBXLP 1 RHEBXLA...

Page 21: ...assembly by fastening the hinges with four screws to the pre punched holes in the cabinet 5 Re install the front glass 6 Install the top louvre by using the hooks to hang it in place KEY DESCRIPTION...

Page 22: ...stall the Control Knobs Extensions onto the appropriate Control Valve Knobs Fig 35 On units fitted with a Honeywell brand control valve the location of the control knobs and the ignitor button may var...

Page 23: ...t interchangeable with the RN RP knobs shown in Fig 35 2 Install the hanging brackets as per Fig 36 3 Install bracket on each side of the cabinet as per Fig 40 4 Install the two ceramic pieces inside...

Page 24: ...im to the steel frame Fig 40 Bracket for HEBTKP Fig 37 Hang the Window Grille or the Steel Frame onto the lower tabs of the Hanging Brackets Fig 38 Engage the slots in the Upper Grille Top Louvre with...

Page 25: ...301200 57946 6 Bottom Louvre Left 1301219 1341219 1301219 7 Bottom Louvre Right 1301218 1341218 1301218 8 Bay Window Centre 1301198 1341198 1409127 1409127 9 Glass Side 1601971 1601971 1601971 1601971...

Page 26: ...d Charcoal Grey HECGR Cast Surround Green CSSP Polished Brass Small Trim for Cast Surround CSLP Polished Brass Large Trim for Cast Surround to be used with CSSP A6 FREESTANDING KITS Convert Insert Int...

Page 27: ...te Air Intake has a Blue Line on the vent FLEX VENT KIT Model HEDVK35 Includes Two 2 3 Dia x 35 ft long compressed Flex Vent Note Air Intake has a Blue Line on the vent 12 x 12 VENT TERMINATION KIT Mo...