ZDA-3280RH Technical Specifications 

 

 

Controls & alarms: 

Input: 

External changeover request 

A ground applied to this input will emulate the operation of the front panel 
switch “Change Request”. 

 

Outputs: 

Bypass 

Contact closure to ground if power has failed. 

General Alarm 

Contact closure to ground if 

 

a. Data Loss is detected OR 

 

b. AIS is detected AND the AIS disable link (LK 1) is not installed. 

 

 

AIS detection is defined as at least

 

2048 consecutive data “1”s. 

 

Data Loss is defined as less than 120 data “1”s in 512 G.703 data rate clock 
periods. 

 

Connectors:

 Data: 

BNC. 

 

Alarm: 

Krone LSA plus. 

 

Changeover logic: 

A changeover to the companion module will occur under any of the following conditions: 

Loss of input signal 
AIS detection alarm (provided AIS is not disabled by link LK 1) 
Loss of power 

In all of the above cases switching will only occur if 

companion module is able to provide an output free of the same defects and 
changeover inhibit switch is not activated on either module. 

 

Priority logic: 

The priority switching in normal mode follows non-reverting logic, which dictates: 

In the event of failure of main then standby DDA will assume control and become 

Main

 causing the failed 

path DDA to become 

Standby

 
This implies that when the failed path is restored that it will remain as 

Standby

 and not become 

Main

 unless either a 

failure of 

Main

 occurs or a manual changeover is requested. 

 

Power on reset. 

When power is applied to the pair, the 

power on reset

 signal will set the module which was last enabled as 

Main

 as 

Main

 and the other module will be forced to act as 

Reserve

 
When power is applied to a pair for the first time it may be necessary to force the desired module to become main by 
pressing the 

Change Request

 button on the front panel of the desired module. The 

Main

 module will be indicated by 

the 

In Service

 LED lighting on the front panel. 

IRT 

Communications 

www.irtcommunications.com

Summary of Contents for DDA-3280

Page 1: ...0 832 575 26 Hotham Parade ARTARMON N S W 2064 AUSTRALIA National Phone 02 9439 3744 Fax 02 9439 7439 International 61 2 9439 3744 61 2 9439 7439 Email sales irtelectronics com Web www irtelectronics...

Page 2: ...cs CCIT G 703 2048 kb s 5 ZDA 3280RH 6 Characteristics of signal 7 Coding Characteristics 7 G 703 Data Signal Format 7 Description of Operation 8 Handshake Operation 10 Pre installation 12 Operational...

Page 3: ...e ZDA 3280RH dual rear assembly must be used When used as a line equaliser or distribution amplifier the DDA may be housed in any of IRT s standard Eurocard frames When used in pairs for handshake ope...

Page 4: ...AY K 1 3 RELAY K 1 2 DDA SIGNAL PROCESSING RELAYS K 3 2RL1 2RL2 INPUT J 1 RELAY K 1 3 RELAY K 1 2 OUTPUTS J 4 RECLOCKING AIS DETECTION DATA FAIL DETECTION MAIN SBY LOGIC FOR K 3 Relay K 1 Power fail b...

Page 5: ...loss AIS detect Module in service Module in standby Other Power requirements 28 Vac CT 14 0 14 or 16 Vdc Power consumption 170 mA 5 5 VA Temperature range 0 50 C ambient Mechanical Suitable for mounti...

Page 6: ...module is able to provide an output free of the same defects and changeover inhibit switch is not activated on either module Priority logic The priority switching in normal mode follows non reverting...

Page 7: ...rve the AC nature of the signal a coding system is used to ensure that a succession of either 1 s or 0 s in the original data does not produce a DC output The coding system varies according to the typ...

Page 8: ...by any external signal present via pin 15a of the rear connector to the reset coil When power is applied to the DDA the logic circuit will cause the K 3 relay to be set If two DDA s are connected in h...

Page 9: ...nts the AIS detection from operating the automatic changeover function when used in handshake configuration and prevents AIS from setting the general alarm output The AIS detection circuit will howeve...

Page 10: ...rear assembly ZDA 3280RH This rear assembly makes all the necessary connections for both logic and data signals when two DDA s are inserted side by side in a 3 RU frame Individual alarm outputs are pr...

Page 11: ...dition and so both will attempt to become Main As the P O R signal for each module will be slightly different for any two modules one will reach its operating mode first and will force the other modul...

Page 12: ...care should be taken to ensure that the frame is connected to earth for safety reasons See frame manual for details Signal earth For safety reasons a connection is made between signal earth and chass...

Page 13: ...required Only good quality 75 Ohm connectors and cable should be used The use of 50 Ohm BNC connectors may cause serious reflection problems with G 703 signals causing data errors In general cable run...

Page 14: ...f connectors indicators and controls only MON ALLOW INHIBIT REQUEST AIS STANDBY CHANGE DATA LOSS IN SERVICE DDA 3280 N140 ZDA 3280RH 1 2 3 4 2SK 2 1J 2 MODULE 1 1J 3 MODULE 2 1J 4 1 2 3 4 2J 1 1J 1 IN...

Page 15: ...ir The equipment should be properly packed for return observing antistatic procedures The following information should accompany the unit to be returned 1 A fault report should be included indicating...

Page 16: ...DA schematic part 1 804066 2 DDA 3280 2 Mb DA schematic part 2 804066 3 DDA 3280 2 Mb DA signal path block diagram 804066 4 DDA 3280 2 Mb DA external logic block diagram 804184 1 ZDA 3280RH Handshake...

Page 17: ...2 1 GEN ALARM 2 1 R62 4K7 2 1 F1 4R7 2 1 F2 4R7 2 1 F3 4R7 2 1 F4 4R7 5 6 U5C HC14S PB1 make_main_req SW1 inhib_co LD1 dataloss_led LD2 ais_led LD3 in_service_led LD4 standby_led 2 1 R61 4K7 2 1 R65 1...

Page 18: ...1 2 C82 1 2 C81 1 2 C80 2 1 3 DD3 BAV70 2 1 3 DD5 BAV70 2 1 3 DD7 BAV70 2 1 R1 300R 3 1 2 RV1 100k 1 2 C3 100n 1 2 C4 33p 1 2 C6 100n 1 2 C7 10u 1 2 C8 100n 1 2 C11 10u 1 2 C12 100n T2 T4 6T L1 48u CT...

Page 19: ...W AUSTRALIA 2064 A3 N T S 5 DDA 3280 804066 Date 6 Feb 2002 CLOCK AND DATA RECOVERY CLOCK MARK MARK AIS DETECTION DATA FAIL DETECTION MAIN SBY LOGIC FOR K3 AMPLIFIER 2MB DATA DISTRIBUTION BLOCK DIAGRA...

Page 20: ...V 5V 5V 5V 5V 12V K2 Gen alarm Make main Inhibit Data loss LED AIS LED In service LED Standby LED 12V K1 5V __ __ __ __ 5V 5V SK2 KRONE Gen alarm Ext C O Req Gnd BLOCK DIAGRAM DDA 3280 EXTERNAL LOGIC...

Page 21: ...1 32B 2SK1 1A 2SK1 2A 2SK1 3A 2SK1 4A 2SK1 5A 2SK1 6A 2SK1 7A 2SK1 8A 2SK1 9A 2SK1 10A 2SK1 11A 2SK1 12A 2SK1 13A 2SK1 14A 2SK1 15A 2SK1 16A 2SK1 17A 2SK1 18A 2SK1 19A 2SK1 20A 2SK1 21A 2SK1 22A 2SK1...

Reviews: