TECHNICAL SPECIFICATIONS 

Data Inputs: 

Number 

Impedance

 

75 

, BNC. 

Type

 

3G-SDI,  HD-SDI,  SD-SDI  or  ASI  (to  SMPTE  424M,  292M  and  259M-C  standards;  and 
DVB-ASI standard). 

Return loss

 

15dB 5 MHz to 1.485 GHz, 

 

10dB from 1.485 GHz to2.97 GHz

1

Equalisation  Automatic

 

100 m at 3G-SDI rate with Belden 1694A

2

 

200 m at HD-SDI rate with Belden 1694

2,3

, 120 m with Belden 8281

2,3

 

400 m at SD-SDI/ASI rate with Belden 1694

3

, 300 m with Belden 8281

3,4

 

Data Outputs: 

Number

 

8 (1 in, 8 out; or (2x) 1 in, 4 out), plus 2 front panel monitoring. 

Type

 

Reclocked or non-reclocked, switch selectable. 

Level

 

800 mV 

±

 10%. 

Impedance

 

75 

, BNC. 

Return loss

 

15dB 5 MHz to 1.485 GHz, 

 

10dB from 1.485 GHz to 2.97 GHz

1

 

Performance: 

Reclocking

 

Automatic or selectable for 3G-SDI, HD-SDI or SD-SDI / ASI operation. 

Rise Time

 

3G/HD

 

< 135 ps at 2.97 Gb/s and 1.485 Gb/s; 

 

SD

 

> 0.4 ns and < 1.5 ns at 270 Mb/s. 

Intrinsic Jitter

 

< 0.3 UI at 2.97 Gb/s reclocked; 

 

< 0.2 UI at 1.485 Gb/s reclocked; 

 

< 0.1 UI at 270 Mb/s reclocked. 

 

Indicators: 

DC

 

LED (green) for module power. 

INPUT A

 

LED (green) when signal present on channel A input (LED flashes if present but not active

5

). 

INPUT B

 

LED (green) when signal present on channel B input (LED flashes if present but not active

5

). 

SD

 

LED  (green)  x2  when  SD-SDI  or  ASI  signal  present  and  locked  to  selected  input  on 
either A or B outputs. 

HD

 

LED (green) x2 when HD-SDI signal present and locked to selected input on either A or 
B outputs. 

3G 

LED (green) x2 when 3G-SDI signal present and locked to selected input on either A or 
B outputs. 

 

Alarm Outputs: 

Alarm A

 

A alarm switches to either open circuit or ground (link selectable) via MOSFET relays 
on either loss of signal or incorrect signal rate on I/P A. 

Alarm B 

B alarm switches to either open circuit or ground (link selectable) via MOSFET relays 
on either loss of signal or incorrect signal rate on I/P B. 

 

Power requirement: 

Voltage

 

28 Vac CT (14-0-14) or 

±

16 Vdc. 

Power consumption

 

< 6 VA. 

 

Other: 

Temperature

 

0 - 50°C ambient. 

Mechanical

 

Suitable  for  mounting  in  IRT  19"  rack  chassis  with  input,  output  and  power 
connections on the rear panel. 

Finish

 

Front panel

 

Grey background, black lettering & red IRT logo. 

 

Rear assembly

 

Detachable silk-screened PCB with direct mount connectors to Eurocard and external signals. 

Dimensions

 

6 HP x 3 U x 220 mm IRT Eurocard. 

Standard

 

Rear connector assembly with matching connector for alarm output. 

Optional

 

ZDA-4010RL relay bypass rear assembly suitable for 3G-SDI

1

, HD-SDI and SD-SDI/ASI signals. 

 

 

NOTE:

 

1

 

Return loss reduced by a couple of dB at 3G rate with optional bypass relay. 

 

 

2

 

Reduces to ~ 50m with optional bypass relay rear assembly. 

 

3

 

If two inputs are being inputted, cable equalisation is limited to that of the higher rate. 

 

 

4

 

Reduces to ~ 70m when SW1-4 (I/P A), SW2-4 (I/P B) is ON. 

 

 

5

 

When automatic change-over function has been set. 

Due to our policy of continuing development, these specifications are subject to change without notice. 

Summary of Contents for DDA-4010

Page 1: ...DDA 4010 IRT Electronics Pty Ltd www irtelectronics com Page 1 of 21 Revision 01 Single 1 In 8 Out Dual 1 In 4 Out 3G HD SD ASI Reclocking Non Reclocking Distribution Amplifier User Manual...

Page 2: ...By Change Description Applicable to 00 03 01 2013 AL Original Issue Issue 3 PCB units fitted with firmware version 2 1 01 03 06 2013 AL DIP switch designators changed to SW1 and SW2 links LK1 and LK2...

Page 3: ...arm Outputs 11 Front and Rear Layouts 12 Operation 13 Single 1 In 8 Out Mode 13 ChAx8 Input A to all 8 Outputs 13 ChBx8 Input B to all 8 Outputs 13 Automatic Changeover Mode 13 Non Reclocking Mode 14...

Page 4: ...itions dangerous potentials may exist in some circuits when power controls are in the OFF position Maintenance personnel should observe all safety regulations Do not make any adjustments inside equipm...

Page 5: ...present and whether the outputs are locked to the inputs An optional relay bypass rear assembly is available to switch the Inputs to one of their respective Outputs in the event of a power failure Si...

Page 6: ...HD LED green x2 when HD SDI signal present and locked to selected input on either A or B outputs 3G LED green x2 when 3G SDI signal present and locked to selected input on either A or B outputs Alarm...

Page 7: ...SW2 2 Auto Detect 3G HD SD ASI rates OFF OFF SD SDI ASI only ON OFF HD SDI only OFF ON 3G SDI only ON ON SW2 3 OFF I P B Reclocking mode DA behaves as a Reclocking DA ON I P B Non Reclocking mode Recl...

Page 8: ...puts if desired ChBx8 Input B to all 8 Outputs 4 x Output A and 4 x Output B Sw1 5 OFF Single 1 In 8 Out DA mode Sw2 5 ON Input B primary input Data Rate For automatic detection of signal type so that...

Page 9: ...ing Mode Sw1 3 OFF Input A reclocked A input behaves as a reclocking DA Sw2 3 OFF Input B reclocked B input behaves as a reclocking DA Non Reclocking Mode Sw1 3 ON Input A non reclocked A input behave...

Page 10: ...nputs Outputs For use with supplied standard rear assembly ZDA 4010 or optional relay bypass rear assembly ZDA 4010RL The DDA 4010 can be configured as a single 1 IN 8 OUT distribution amplifier or as...

Page 11: ...hBx8 mode alarm A is non functional regardless of input A s status unless automatic changeover mode is also set If in the dual ChAx4 ChBx4 mode both alarms A and B are functional regardless of whether...

Page 12: ...DDA 4010 IRT Electronics Pty Ltd www irtelectronics com Page 12 of 21 Revision 01 Front rear panel connector diagrams ZDA 4010 Standard Rear Assembly ZDA 4010RL 3G HD SD ASI Relay Bypass Rear Assembly...

Page 13: ...t data rate signal such as HD SDI Unless Automatic Changeover mode has been implemented even if a signal has been applied to the IN A port INPUT A will not illuminate See Automatic Changeover descript...

Page 14: ...ode if an input signal is present the corresponding front panel INPUT LED will illuminate but the 3G HD and SD LEDs will not except in the case where the input data rate actually corresponds to a 3G H...

Page 15: ...data rate the corresponding input and detected data rate LEDs will flash and the corresponding outputs will be muted unless the Automatic Changeover function has been implemented see Automatic Change...

Page 16: ...nd B has been set for the SD SDI only rate Input A is being fed by a signal at the SD rate which is being fed to B s outputs as indicated by the INPUT A LED not flashing whilst A s SD data rate LED is...

Page 17: ...ion and translates that information into a form compatible with SNMP The agent therefore acts as an interface between the NMS and the managed devices The NMS sends a request message and control comman...

Page 18: ...that are SNMP compatible may need an optional plug in SNMP module with a program relevant to the module that it is plugged into Depending on the module besides the module identification parameters su...

Page 19: ...x4 Dual 1x4 DA IN A OUT 1A to OUT 4A IN B OUT 1B to OUT 4B 2 chAx8 Single1x8DA INAprimaryinput INA OUT1AtoOUT4A OUT1BtoOUT4B 3 chBx8 Single1x8DA INBprimaryinput INB OUT1BtoOUT4B OUT1AtoOUT4A autoChang...

Page 20: ...Reclocker enable bypass option is not applicable to the secondary input of a single 1x8 DA mode If the user sets this parameter to na the reclocker will default to the enabled setting alias A 16 chara...

Page 21: ...re Warranty on components shall be extended by IRT only to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be servic...

Reviews: