Replacing the glass and door rope

To maintain a safe operation of the stove door any 
damaged glass should be replaced immediately.  Remove 
the door by lifting from the hinges and lay down on a soft 
flat surface.  Remove the glass fixing strips and fit new glass 
into position.  Be careful not to overtighten the screws as 
this can break the glass.  To fit a new door seal remove the 
rope and any residue adhesive.  Insert rope adhesive into 
the channel and replacement rope.  Wait approximately 12 
hours for the rope adhesive to set before using the stove.

Glass dimensions: 407mm x 310mm

Rope diameter: 10mm (soft rope)

Seasonal use

Over the summer months, when the stove is not in use 
remove all ash and soot from within the ash pan and above 
the baffle plate. Set the air control to the halfway position 
as this will reduce any build-up of moisture in the stove 
and reduce any corrosion.  In the event that there is rust 
on any of the components this can be removed using wire 
wool and 2 light coats of stove paint.  

After a prolonged period of not using the 
appliance check for blockages will need to be 
made before re-lighting.

Summary of Contents for IW W5kW

Page 1: ...5kW Wide Woodburning Stove User Instruction Manual Issued June 2021 Document No IW5WM01...

Page 2: ...ired see care maintenance Do not make any unauthorised modifications or changes to the appliance Do not place combustible materials such as fuel close or in close proximity to the appliance Furniture...

Page 3: ...ste wood eg old furniture pallets or fence panels or household rubbish Treated waste wood and household rubbish can emit harmful fumes and toxic pollutants into your home when burnt Do not use liquid...

Page 4: ...ring and damage the appliance STEP 2 Moving towards optimum temperature When an optimum temperature of between 150 and 250 Celsius on the outer body of the stove is reached push the slider again furth...

Page 5: ...e metal container Do not place hot ash in a container made from plastic or combustible material Ash can remain hot for a long period of time after use ensure sufficient time has lapsed before removing...

Page 6: ...f the pipe to allow a tight fit A mechanical fixing such as a self tapping screw or rivet is required to secure the pipe into position While this connection is made we advise to lift the stove top in...

Page 7: ...on the requirements of the Clean Air Act can be found here at https www gov uk smoke control area rules Your local authority is responsible for implementing the Clean Air Act 1993 including designatio...

Page 8: ...pply of air to maintain good combustion Extractor fans or cooker hoods must not be placed in the same room as this can cause fumes to emit into the room Care Maintenance Annual service Before the star...

Page 9: ...front opening of the stove To remove the rear firebrick the grate is to be moved vertically and then taken out of the front opening of the fire Only use replacement parts supplied or recommended by I...

Page 10: ...lacement rope Wait approximately 12 hours for the rope adhesive to set before using the stove Glass dimensions 407mm x 310mm Rope diameter 10mm soft rope Seasonal use Over the summer months when the s...

Page 11: ...e and over heating High flue draft Consult your installer who may advise use of an anti downdraft cowl Excessive fuel use Fuel too dry Do not use constructional timber or pallet wood Excess air into f...

Page 12: ...Tel 01446 771567 www ironwoodstoves co uk...

Reviews: