Intended Use 

The Ironton 25Ft. Handheld Drain Cleaner is professionally engineered to clean 1 ¼ inch to 2 ½ inch 
diameter drain lines up to 25 feet. 

Technical Specifications 

Property 

Specification 

Power 

300W 

Speed 

0-600RPM 

Cord Length 

25ft. 

Cord Diameter 

1/4in. 

Important Safety Information 

WARNING

 

 

Read and understand all instructions. Failure to follow all instructions may result in serious injury 
or property damage. 

 

The warnings, cautions, and instructions in this manual cannot cover all possible conditions or 
situations that could occur. Exercise common sense and caution when using this tool. Always be 
aware of the environment and ensure that the tool is used in a safe and responsible manner.  

 

Do not allow persons to operate or assemble the product until they have read this manual and 
have developed a thorough understanding of how it works. 

 

Do not modify this product in any way. Unauthorized modification may impair the function and/or 
safety and could affect the life of the product. There are specific applications for which the product 
was designed.  

 

Use the right tool for the job. DO NOT attempt to force small equipment to do the work of larger 
industrial equipment. There are certain applications for which this equipment was designed. This 
product will be safer and do a better job at the capacity for which it was intended. DO NOT use 
this equipment for a purpose for which it was not intended. 

 

Industrial or commercial applications must follow OSHA requirements. 

 

WARNING

 

WORK AREA SAFETY 

 

Inspect the work area before each use. Keep work area clean, dry, free of clutter, and well-lit. 
Cluttered, wet, or dark work areas can result in injury. Using the product in confined work areas 
may put you dangerously close to cutting tools and rotating parts. 

 

Do not use the product where there is a risk of causing a fire or an explosion; e.g., in the presence 
of flammable liquids, gases, or dust. The product can create sparks, which may ignite the 
flammable liquids, gases, or dust. 

 

Do not allow the product to come into contact with an electrical source. The tool is not insulated 
and contact will cause electrical shock. 

 

Keep children and bystanders away from the work area while operating the tool. Do not allow 

Summary of Contents for 61527

Page 1: ...Drain Cleaner Owner s Manual WARNING Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may re...

Page 2: ...that you read the entire manual to become familiar with this product before you begin using it This drain cleaner is designed for certain applications only Northern Tool and Equipment is not responsib...

Page 3: ...t Safety Information 4 Specific Operation Warnings 6 Grounding 6 Extension Cords 8 Main Parts of Drain Cleaner 9 Before Each Use 9 Operating Instructions 10 After Each Use 12 Maintenance 13 Troublesho...

Page 4: ...are specific applications for which the product was designed Use the right tool for the job DO NOT attempt to force small equipment to do the work of larger industrial equipment There are certain app...

Page 5: ...pply or turning on the tool A wrench or key that is left attached to a rotating part of the tool may cause personal injury Secure the work with clamps or a vise instead of your hand when practical Thi...

Page 6: ...pipe use the front guide tube If the distance is too long it may cause winding or it may break off of the flexible shaft Do not operate the drain cleaner while reversing pressing the forward and rever...

Page 7: ...g in the plug is connected through the green wire inside the cord to the grounding system in the tool The green wire in the cord must be the only wire connected to the tool s grounding system and must...

Page 8: ...e smaller the wire s gauge number the greater the capacity of the cord For example a 14 gauge cord can carry a higher current than a 16 gauge cord Minimum extension cord wire size is shown in the foll...

Page 9: ...are no damaged machine parts that may pose a threat to your safety Lubricate the flexible shaft according to this manual Check to be sure the flexible shaft is not worn or damaged If it is immediatel...

Page 10: ...operate the drain cleaner while reversing pressing the forward and reverse rotation button R Operating in the R state can cause damage to the flexible shaft The button R is only used to exit the flexi...

Page 11: ...forward to the F position and the flexible shaft will move forward 3 Press the speed switch lightly and pull the handle back to the R position The flexible shaft will retract 1 When the forward and r...

Page 12: ...ws with an Allen wrench not included and remove the unwanted flexible shaft 4 Insert the new flexible shaft into the connector align the screw holes and tighten the M4 set screws again 5 Push the flex...

Page 13: ...sed Keep your tool in good repair Keep handles dry clean and free from oil and grease The following chart is based on a normal operation schedule Maintenance Interval Maintenance Point Daily before op...

Page 14: ...Page 14 of 18 Parts Diagram...

Page 15: ...lve 1 20 Drum 1 21 O Seal ring 1 22 Waterproof plug 1 23 Screw M6 60 1 24 Flash washer 1 25 Left cover 1 26 Locating plate 1 27 Screw M6 16 6 28 Bearing 606 6 29 Bearing base 1 30 Spring 6 22 2 31 Ste...

Page 16: ...l product components are available for replacement The illustrations provided are a convenient reference to the location and position of parts in the assembly sequence When ordering parts the followin...

Page 17: ...claim contact Us at 1 800 222 5381 identify the product by make and model number and follow the claim instructions that will be provided The product and the purchase receipt must be provided to Us in...

Page 18: ...Page 18 of 18 Distributed by Northern Tool Equipment Company Inc Burnsville Minnesota 55306 www northerntool com Made in China...

Reviews: