ATTACHING SAFETY IN OPERATION WARNINGS

It is required that the set of safety instruction labels 

that have been furnished with the appliance be affixed 

to the operation and control points of the appliance. A 

safety instruction label should be affixed next to the 

burner control switch where the appliance is turned 

on and off 

(See 

Figure A

)

 and the remote control 

handheld transmitter 

(See 

Figure B

)

.  To properly 

complete the installation of this appliance, locate the 

multi-lingual adhesive labels provided with these 

instructions and proceed as follows:

1.  Locate the control switch on the control panel 

of your appliance (verify the switch operates the 

appliance by turning it on and off).  Clean the 

surface on the control panel thoroughly to remove 

any dust and oils. Affix the label next to the burner 

control switch that controls the appliance 

(

Figure 

A

)

.   Choose the language primarily spoken in the 

home. If unknown, affix the English language 

label.

2.  Locate the remote control transmitter and clean 

it thoroughly to remove any dust and oils.  Affix 

the label to the surface of handheld transmitter 

(

Figure B

)

.  Choose the language primarily 

spoken in the home. If unknown, affix the English 

language label.

3.  If you are unable to locate the labels, please 

contact IHP or your nearest IHP dealer to receive 

additional safety instruction labels free of charge.

Cat. No. H8024 Replacement Label Kit 

IHP

IronStrike.us.com

NOTE: English is red text on clear label. French 

and Spanish are white text on black label.

APPOSITION DES MISES EN GARDE RELATIVES 

À LA SÉCURITÉ D’UTILISATION

Il est impératif que le jeu d’étiquettes de sécurité qui 

ont été fournies avec le foyer soient collées à côté des 

dispositifs de contrôle du impératif. Une étiquette de 

sécurité devrait être collée sur la plaque du récepteur 

contrôlant l’allumage de l’appareil 

(voir 

Figure A

)

 et sur 

le boîtier de la télécommande 

(

Figure B

)

. Les mises en 

garde auraient dû être collées au moment de l’installation 

initiale de l’appareil. Si ce n’est pas le cas, prenez les 

étiquettes adhésives multilingues fournies avec ces 

instructions et procédez comme suit :

1.  Repérez le contrôleur sur le panneau de contrôle de 

votre appareil (vérifiez que l’interrupteur contrôle 

le fonctionnement de l’appareil en le faisant 

basculer de Marche à Arrêt, et vice-versa). Nettoyez 

soigneusement la surface sur le panneau de contrôle 

pour éliminer la poussière et les traces de graisse 

ou d’huile. Collez l’étiquette à côté du bouton de 

contrôle du brûleur qui contrôle l’appareil 

(

Figure 

A

)

. Choisissez la langue qui est principalement parlée 

dans la résidence du propriétaire. En cas de doute, 

collez l’étiquette en anglais.

2.  Repérez la télécommande et nettoyez-la soigneuse-

ment pour éliminer la poussière et les traces 

de graisse ou d’huile.  Collez l’étiquette sur le boîtier de 

la télécommande 

(

Figure B

)

.  Choisissez la 

langue qui est principalement parlée dans la 

résidence du propriétaire. En cas de doute, collez 

l’étiquette en anglais.

3.   Si vous ne parvenez pas à localiser les étiquettes, s’il 

vous plaît contactez IHP ou votre revendeur le plus 

proche pour recevoir IHP étiquettes d’instructions 

de sécurité supplémentaires gratuitement.
Étiquettes de remplacement, n° cat. H8024 

IHP

IronStrike.us.com

Remarque : Le texte anglais est rouge sur un support 

transparent. Le texte français et espagnol est blanc 

sur un support noir.

COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD 

EN OPERACIÓN

Se requiere que el juego de etiquetas de instrucciones 

de seguridad que se incluyeron con la artefacto  se 

coloque en los puntos de operación y control de la 

misma. Se debe colocar una etiqueta de instrucciones 

de seguridad adyacente al interruptor de control del 

quemador donde se enciende y se apaga el artefacto 

(ver la 

Figura A

)

 y en el transmisor de control remoto 

(

Figura B

)

. Las advertencias ya deben haberse colocado 

cuando se completó la instalación inicial del artefacto. 

Si no están colocadas en estos lugares, encuentre las 

etiquetas adhesivas multilingües proporcionadas con 

estas instrucciones y prosiga de la siguiente manera:

1.  Identifique el interruptor de control en el panel de 

control del artefacto (verifique que el interruptor 

opera el artefacto encendiéndolo y apagándolo). 

Limpie bien la superficie del panel de control para 

quitar el polvo y aceite. Pegue la etiqueta adyacente 

al interruptor de control del quemador que controla 

el artefacto 

(

Figura A

)

. Seleccione el idioma que 

más se habla en la casa. Si no sabe cuál es, use la 

etiqueta en inglés.

2.  Identifique el transmisor de control remoto y límpielo 

bien para quitar el polvo y aceite. Pegue la etiqueta 

en la superficie del transmisor 

(

Figura B

)

. Seleccione 

el idioma que más se habla en la casa. Si no sabe 

cuál es, use la etiqueta en inglés.

3.  Si no puede encontrar las etiquetas, sírvase llamar 

a Innovative Hearth Products o al distribuidor de 

Innovative Hearth Products más cercano para 

recibir etiquetas de instrucciones de seguridad 

adicionales gratuitas. 

Juego de etiquetas de repuesto - Nº de cat. H8024 

IHP

IronStrike.us.com

Nota: La etiqueta en inglés es transparente con texto 

rojo. Las etiquetas en francés y español son negras 

con texto blanco.

INSTALLER INSTRUCTIONS -

 

ATTACHING SAFETY IN OPERATION WARNINGS

It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a 

critical step in informing consumers of safe operation of this appliance.

SAFETY LABEL 

DIAGRAMS

DIAGRAMAS DE ETIQUETAS 

DE SEGURIDAD

DIAGRAMMES DES ÉTIQUETTES 

DE SÉCURITÉ

Summary of Contents for Ravenna RDV33 IPI

Page 1: ...ly call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a...

Page 2: ...O CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact ac...

Page 3: ...o Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros l quidos inflamable...

Page 4: ...t Leveling 14 Fan Control Module Switch RDV 33 40 TCC models only 15 Installation 15 21 Venting Installation 15 Zero Clearance Fireplace Installation 17 USING THIS MANUAL Please read and carefully fol...

Page 5: ...ls viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une ba...

Page 6: ...ing es proporcionadas con estas instrucciones y prosiga de la siguiente manera 1 Identifique el interruptor de control en el panel de control del artefacto verifique que el interruptor opera el artefa...

Page 7: ...pareil Figure A Choisissezlalanguequiestprincipalementparl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Rep rezlat l commandeetnettoyez lasoigneuse ment pour limi...

Page 8: ...se or anemia those under the influence of alcohol and those at high altitudes Turn off gas and electrical power to the appliance and allow it to cool before cleaning or servicing the appliance If the...

Page 9: ...ver use solid fuels such as wood paper cardboard coal or any flammable liquids etc in this appliance Plated surfaces must be cleaned with glass cleaner and a clean soft cloth before firing the first t...

Page 10: ...ural gas or propane Is NOT for use with solid fuels Is approved for sitting rooms and or bedrooms This appliance is suitable for installation into masonry or factory built fireplaces Fireplace Require...

Page 11: ...a nationally recognized testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This appliance has been tested and certified to ANSI Z21 88 CS...

Page 12: ...rmation This appliance comes from the factory equipped to burn natural gas at a specified elevation Only IHP conversion kits can be used to convert from NG to LP or LP to NG Contact your IHP dealer fo...

Page 13: ...A 31 1 2 800mm Front Opening Width B 19 1 2 495mm Height C 18 457mm Rear Width D 16 406mm Fireplace Depth Top View Left Side View Right Side View Front View A B C D Figure 3 Minimum Fireplace Cavity...

Page 14: ...screws Repeat these steps for each adjusting leg Facing and Mantel Clearances Please note that the RDV33 IPI TCC mantel clearances are 4 less than the RDV40 IPI TCC mantel clearances as shown in Figu...

Page 15: ...tructions for installation and vent termination These appliances are approved for use with the following vent kits Amerivent Flex Liner 3 X 35 3AFL 35 Adaptor w Flashing 4DCAT33 Termination Cap 4DVC S...

Page 16: ...e sealed around the vent pipes Use a non combustible seal off plate i e 22 gage sheet steel or unfaced fiberglass insulation 8 lb per square foot density minimum to seal around the vent pipes Whicheve...

Page 17: ...000 BTU Natural Gas Input To convert input from 40 000 BTU s to 33 000 BTU s Assuming the front door is already removed 1 Remove the log rack Use a 5 32 allen wrench by removing two screws on the fron...

Page 18: ...oundpanelsinfrontoftheholesonthesurroundbrackets Next insert two slotted 1 4 truss screws for each side surround panel and secure loosely 5 Fasten the top surround panel with the remaining two truss s...

Page 19: ...e Figure 15 The panel has keyhole slots where it mounts to the base Loosen the two nuts securing the panel using 3 8 wrench Carefully move out the panel far enough to access the back Do not pull the p...

Page 20: ...ak test solution retighten if necessary If the pressure is not sufficient make sure the gas supply line is large enough the supply regulator is properly adjusted and the total gas load for the residen...

Page 21: ...r will result in bigger flames and more color To adjust the air shutter insert a regular screwdriver into the slide adjustment and slide it side to side see Figures 19a and 19b CAUTION The air shutter...

Page 22: ...r 9 If the appliance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier TO TURN OFF GAS TO APPLIANCE 1 Turn the burner ON OFF switch...

Page 23: ...e SIT Proflame Stepper Electronic Pilot Assembly Electronic Pilot Assembly Unit Mounted Controls Unit Mounted Controls Intermittent Standing Pilot Mode On Auto Pilot Mode Switch Thisappliancecanbeswit...

Page 24: ...s to indicate that it is ready to synchronize with the Remote transmitter Install 3 AAA type batteries in the Remote transmitter battery bay located on the base of the Remote With the batteries alread...

Page 25: ...d off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position see...

Page 26: ...r proper main burner operation at both high and low flame OPERATION RDV33 40 TCC Models Only No Blue Flame Center Soot at Flame Tip Dark Orange Flame IMPROPERLY BURNING FLAME Soot above Flame Tip No S...

Page 27: ...MOTE RECEIVER BLOWER SPEED CONTROL PILOT ON AUTO SWITCH AC DC ADAPTER POWER OUTLET BOX 6 WHT 5 BLUE WHT BLK WHT BLK BLK BLK 4 GRN GRN 8 GRN 3 GRAY 14 RED 9 GRN 2 RED 1 RED 3 BLK 2 BLK 1 RED PILOT ROOM...

Page 28: ...10 ORG 13 BLK 12 BRN 14 RED 4 PUR WHT BLK BLK WHT 4 GRN 8 GRN 2 BLK 3 BLK 1 RED 9 WHT 3 GRAY 2 RED GRN 1 2 3 4 1 Figure 28C Electronic Control Schematic Models RDV33 40 TCC NOTE SWITCH CONDITIONS GIVE...

Page 29: ...n those approved for use with this appliance o Check that the chimney and its outlet are open and free of soot block age or debris The venting system should be periodically examined by a qualified age...

Page 30: ...doors or replace cracked or broken glass Handle this glass with extreme care Glass is susceptible to damage Do not scratch or handle roughly while reinstalling the glass door frame The glass door s o...

Page 31: ...Unplug the power supply cord from the electrical outlet prior to removing theblower Theblowercanbeaccessedthroughthebackwallofthefirebox Remove the insert face glass door log set and firebox liner pan...

Page 32: ...art No J7510 2 Place sight obstructers back over the threaded studs taking note that the upper and lower horizontal bar ends line up with grooves in sight obstructers see Detail A in Figure 33 3 Reins...

Page 33: ...llation on Pages 17 and 18 The main Burner comes on but then goes out Gas is not reaching the appliance Loose wires to the valve or ignition module Pilot flame is not engulf ing the sensor Obstructed...

Page 34: ...with Manual Hi Lo Regulator 26 H8507 Cassette Assembly NG 40 000 BTU if LP also requires H8459 Conversion Kit For Models RDV TCC with Auto Hi Lo Regulator 27 H8490 3 8 NPT Pipe Nipple 8 28 H8498 Air S...

Page 35: ...STRATIONS ARE NOT TO SCALE REPLACEMENT PARTS RDV33 40 IPI RDV33 40 TCC 14 36 25 33 34 21 22 23 13 32 31 30 29 28 1 27 26 2 3 4 5 15 6 7 16 37 8 17 9 10 11 20 19 33 21 34 22 23 12 24 18 38 Facade Cast...

Page 36: ...ruction sheets included in kits Orifice Kits Main Burner 33 000 BTU converts from standard 40 000 BTU input to optional 33 000 BTU input Cat No Description H5924 Orifice Main Burner 36 Natural Gas 33...

Page 37: ...29 x 48 Black Trim Includes black trim x x x H8556 RDV DBV FP3341 D 33 x 41 Black Trim Includes black trim x x x H8557 RDV DBV FP3348 D 33 x 48 Black Trim Includes black trim x x x 75362 RDV DBV FP294...

Page 38: ...wing below Cat No Model Description 75156 RDV DBV PCFP3044 TOP Top Box 1 of 2 75157 RDV DBV PCFP3044 SIDES Sides Box 2 of 2 Pillar Cast Face Kits u Note 3 boxes to complete face 37 5 8 W x 23 3 4 H F2...

Page 39: ...1 8 49 36 51 UNIT FACTORY EQUIPPED FOR 0 2000 FT 0 610 M IN CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777...

Page 40: ...PED FOR 0 2000 FT 0 610 M IN CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635 THIS APPLIANCE MUS...

Page 41: ...iance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any e...

Page 42: ...42 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTES...

Page 43: ...mage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions prov...

Page 44: ...s should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model numb...

Reviews: