IRIS 600 Ultra Applications Manual Download Page 5

ROD

FAULT

FLAME ROD

GOOD

TAP

COIL

ROD

FOULED

GAIN 1

GAIN 2

NO JMPR = MAX GAIN 4

SIGNAL

Relay On

WEAK

SIGNAL

Relay On

POOR

SIGNAL

Relay Off

MODEL 600 ULTRA

GND

115 VAC  50/60 HZ

230 VAC  50/60 HZ

COIL

ROD/

XFMRXFMR

AC

IGN

COM

IGN

DC

IGN

RF A RF A RF A RF B

GAIN 3

RF B RF B

TURN IGN ON

TO XFMR

LINE INPUT

SELECT FOR LINE INPUT

ROD

FLAME

ROD

IGNITION/FLAME

IGNITION

COIL

GAIN 1

GAIN 2

NO JMPR = MAX GAIN 4

GAIN 3

.5A

OR

5A

.5A

OR

5A

FLAME ROD ONLY

AC IN

GND

TO IGN XFMR

TAP

COIL

COIL

ROD/

P1

P2

P3

P4

P5

GND

C

B A

COIL TIP

GND

GND

230 VAC POSITION

115 VAC POSITION

FIGURE 2 - WIRING FOR MODEL 600 FLAME ROD ULTRA

Summary of Contents for 600 Ultra

Page 1: ...FLAME MONITORING SYSTEM WORLD LEADER IN FLAME MONITORING MODEL 600 ULTRA FLAME ROD APPLICATION MANUAL ...

Page 2: ...vided The flame rod itself can be shorted to ground indefinitely without harm to the unit If the flame rod becomes fouled so that an unreasonably large amount ofAC current flows from the flame to ground first a yellow ROD FOULED LED is turned on If the AC current in creases further a ROD FAULT LED is turned on and the flame relay is opened Note that the Model 600 Ultra controller distinguishes bet...

Page 3: ...ntroller Remove the three black screws on each side of the controller lift off the top assembly unplug the two 5 A fuses plug in the two 5 A fuses and reassemble the controller FRONT PANELFUNCTIONSAND SETUP Six numeric LED digits arranged vertically provide a graphic visual display of the flame signal If the Flame Rod is connected and the AC power is on green POWER LED will be on and there is no f...

Page 4: ... ROD GOOD SIG A ROD ROD FOULED GAIN 1 GAIN 2 NO JMPR MAX GAIN 4 SIGNAL Relay On WEAK SIGNAL Relay On POOR SIGNAL Relay Off MODEL 600 ULTRA GND 115 VAC 50 60 HZ 230 VAC 50 60 HZ SIG B ROD XFMRXFMR AC IGN COM IGN DC IGN RF A RF A RF A RF B GAIN 3 RF B RF B TURN IGN ON TO XFMR LINE INPUT SELECT FOR LINE INPUT P1 P2 P3 P4 P5 ...

Page 5: ...D XFMRXFMR AC IGN COM IGN DC IGN RF A RF A RF A RF B GAIN 3 RF B RF B TURN IGN ON TO XFMR LINE INPUT SELECT FOR LINE INPUT ROD FLAME ROD IGNITION FLAME IGNITION COIL GAIN 1 GAIN 2 NO JMPR MAX GAIN 4 GAIN 3 5A OR 5A 5A OR 5A FLAME ROD ONLY AC IN GND TO IGN XFMR TAP COIL COIL ROD P1 P2 P3 P4 P5 GND C B A COIL TIP GND GND 230 VAC POSITION 115 VAC POSITION FIGURE 2 WIRING FOR MODEL 600 FLAME ROD ULTRA...

Page 6: ...rent 02 A DC at 50 VDC 015 A RMS at 230 VAC MaximumCapacitanceLoad 1 0nF flame rod drive to ground through wire insulation OUTPUTS FlameRelay DPDT contacts rated 5Aat 125 VAC 277 VAC and 30 VDC IgnitionTransformerRelay DPST contacts rated 5Aat 125 VAC and 250 VAC IgnitionCoilDrive Acapacitance of 4 4 uF is discharged from 230 VDC through the ignition coil tap at theAC line rate by a 4A 400 V SCR E...