irinox CP One Use And Maintenance Instructions Download Page 5

All necessary precautions must be adopted when 

handling the appliance in order not to damage it, 

respecting the indications on the packaging.

5

1.  GENERAL DOCUMENTATION 

1.1. GENERAL WARNINGS

1.2  INTRODUCTION

1.3  TRANSPORT AND HANDLING

Table 1

•  

•  

•  

•  

•  

•  

•  

This manual is an integral part of the product, it 

supplies all of the indications necessary for correct 

installation, correct use and maintenance of the 

machine.

It is mandatory for the user to read this manual care-

fully and always make reference to it. Moreover, it 

must be kept in a place that is known and accessible 

to the authorised operators (installer, user, mainte-

nance technician)

The holding cabinet is intended for professional use 

and therefore only qualified staff can use it.

The holding cabinet is intended only for the use for 

which it has been designed, i.e. for storage of food 

products.

Products that require constant temperature control 

and recording are excluded, such as:

- heat reactive chemicals
- medicines
- blood products

The manufacturer declines any liability for any damage 

caused by incorrect or unreasonable use, such as for 

example:
- improper use by untrained staff.
- modifications or interventions that are not specific

  for the model.
- use of non-original spare parts or that are not

  specific for the model.
- failure to comply, even partial, with the instructions

  in this manual.

Installation must be carried out by authorised and 

specialised staff, respecting the instructions in this 

manual. The manufacturer declares and assigns to 

each individual machine a Declaration of Conformity to 

the 2006/42/EC Machinery Directive, to the 2006/95/EC 

Low Voltage Directive and to the 2004/108/EC Electro-

magnetic Compatibility Directive. 

Whenever the machine is supplied with the remote 

condensing unit, it is the installer's responsibility to check 

all connections and issue a declaration of perfect execu-

tion that is in compliance with the provisions of the above-

mentioned Directive. The joints made by IRINOX S.p.a. 

are in compliance with Standard EN14276-2.

IMPORTANT NOTE:

 IRINOX reminds you that all 

machines must be subjected to periodic inspections in 

compliance with the national standards in force. 

In particular for the Italian market: a complete control of 

the plant must be carried out and especially an inspec-

tion of the integrity of the cooling circuits under pres-

sure after ten years of operation as a set, as required in 

Italy by Annex B of the Italian Ministerial Decree no. 

329 of 1 December 2004 for sets belonging to catego-

ries from I to IV containing group 2 fluids.

NET

WEIGHT

kg

CARDBOARD PACKAGING

CRATE PACKAGING

L

 

(mm)

  H

 

(mm)

D

 

(mm)

m

3

kg

Holding cabinet model

Condensing unit (if remote)

CP ONE

Condensing unit

240

840

2270

1190

2,27

275

L

 

(mm)

  H

 

(mm)

P

 

(mm)

m

3

kg

930

2320

1230

2,65

410

38

690

450

720

0,22

58

700

450

780

0,25

76

Summary of Contents for CP One

Page 1: ...U S E A N D M A I N T E N A N C E I N S T R U C T I O N S REV No REVISION DESCRIPTION REV DATE PROOF READER 00 26 10 2015 L B FIRST EMISSION 01 10 09 2017 D N ADDED GAS R452A...

Page 2: ...you for having chosen IRINOX Please take the time to read this manual carefully to make the most of all the potential and benefits of your new CP ONE We would like to remind you that the perfect opera...

Page 3: ...the connection regulations Use gloves suitable for cold trays During cleaning operations especially of the condenser always wear protective gloves glasses and masks for protection of the respiratory t...

Page 4: ...CONNECTION 9 2 7 REFRIGERATOR CONNECTION 10 2 8 CONDENSATE DRAIN 11 2 9 WATER COOLING UNITS CONNECTION 11 2 10 NOTES FOR THE INSTALLER 12 2 11 SAFETY AND CONTROL SYSTEMS 12 2 12 R404A R452A GAS SAFETY...

Page 5: ...with the instructions in this manual Installation must be carried out by authorised and specialised staff respecting the instructions in this manual The manufacturer declares and assigns to each indiv...

Page 6: ...ned place see par 2 2 After the packaging has been removed check the integrity of the holding cabinet Remove the protective PVC film from all sides Fig 1 When handling the packaging and the wooden bas...

Page 7: ...level the appliance Do not use the forklift truck to straighten the machine as it could damage the basin guides on the bottom of the machine Fig 3 If the appliances are not levelled their functioning...

Page 8: ...8 2 3 DIMENSIONAL DATA 810 A A B B 2085 1970 56 670 1053 5 1347 871 5 SECTION B B SECTION A A Service Area 250...

Page 9: ...l data sheets The voltage of the systems must be within the limit of 10 and the voltage distortion of the phases must not exceed 3 The electrical power connection must be performed by qualified staff...

Page 10: ...cabinet holder s heat exchangers can be shut off from the rest of the plant via valves these exchangers must be protected by suitable safety devices as forese en by the Standard EN378 2 2008 A1 2009...

Page 11: ...isolante del tipo a cellule chiuse di buona qualit dello spessore minimo di 19 mm Table 7 Flow line mm Intake line mm Hot gas line mm Pipes maximum length 15 m 6 12 10 19 mm 2 9 WATER COOLING UNITS C...

Page 12: ...vation cycle reach the set temperature and one manual defro sting cycle Inform the customer regarding the exact use of the appliance with specific reference to use and the requirements of the customer...

Page 13: ...ble that it is dangerous due to cutaneous absorption Repeated and prolonged contact can cause the removal of sebaceous matter with consequent dryness cracking and dermatitis Ecological information It...

Page 14: ...appliance or package indicates that at the end of the product s life it must be collected separately from other waste The separate waste collection of this appliance at the end of its life is organis...

Page 15: ...resh products or for brief periods of cooked food NEGATIVE Mode 20 C suitable for the preserva tion of frozen products also for long periods of time CHOCOLATE Mode 14 C suitable for the preserva tion...

Page 16: ...g the minutes press P5 to confirm and save the clock setting rtc appears on the display The indicator goes off Description Phase 1 With the cabinet holder in Stand by select the operating mode See par...

Page 17: ...Ur2 average humidity Ur3 high humidity Press P1 to confirm the data entered and exit the menu If no key is pressed after a pre set time one automatically exits the menu and the entered data is saved O...

Page 18: ...temperature unit of measurement is F The instrument is in standby Steady Flashing Change temperature set point Compressor run requested but pending safety time end Defrosting in progress but pending c...

Page 19: ...ing the machine on empty until the operating temperature is set In order to have good machine performance and not have deterioration of food we recommend you Make sure that a sufficient space is left...

Page 20: ...intenance operation disconnect the machine from the electrical power supply by turning the main switch off and remo ving the plug do not pull the power supply cable to disconnect the machine from the...

Page 21: ...visual signal system which signals the presence of an alarm press a key to silence the sound alarm Meaning Minimum temperature HACCP alarm Maximum temperature HACCP alarm Open door HACCP alarm No vol...

Page 22: ...e connection to the electrical line No coolant gas Technician intervention No power supply Check the connection to the electrical line Faulty fan Intervention of a technician to replace the fan No ele...

Page 23: ...aintenance operations accurately reas semble the covers and tighten the locking screws Fig 28 Fig 29 For correct and efficient functioning of the cabinet holder the air condenser must be kept clean in...

Page 24: ...OX headquarter via Madonna di Loreto 6 B 31020 Corbanese di Tarzo TV Italy production site via Caduti nei lager 1 Z I Prealpi Trevigiane loc Scomigo 31015 Conegliano TV Italy P 39 0438 2020 F 39 0438...

Reviews: