5: APPENDICES
Iridium Pilot Land Station Installation Guide
39
Appendix C – ODU/IDU Cable
ODU/IDU Interface Cable Drawing
Notes:
1. IDU connector to be RJ-45 shielded, connected as per table. Use Stewart Connector Part number
943-SP-370808SM2 or equivalent.
2. The ODU connector is Bulgin Buccaneer PX0728/S connected per the table below. To maintain weather
proof seal the connector gland nut must be tightened to 10 lbf-inches of torque.
3. Cable to be marine grade, tri-shielded network cable such as Belcom part number M4884969 or equivalent.
4. The cable maximum length is 50 m. The combined length of the ODU/IDU interface cable plus the
Computer-to-Data port cable shall not exceed 100 meters total length to comply with Ethernet maximum
length standards.
5. If installer is not using Iridium provided cables and is creating a cable, please follow the pin out instructions
as detailed below.
ODU Connector
Conductor Color
Standard (T568A)
IDU Connector
I
White/Orange stripe
3
2
Orange solid
6
3
Brown solid
8
4
(drain wire)
SHIELD
5
White/Brown stripe
7
6
Green solid
2
7
White/Green stripe
1
8
Blue solid
4
9
White/Blue stripe
5
Summary of Contents for Pilot TPIM1301
Page 5: ...iv Iridium Pilot Land Station Installation Guide...
Page 11: ...1 INTRODUCTION 6 Iridium Pilot Land Station Installation Guide...
Page 29: ...2 INSTALLATION 24 Iridium Pilot Land Station Installation Guide...
Page 33: ...3 NETWORK CONFIGURATION 28 Iridium Pilot Land Station Installation Guide...
Page 40: ...5 APPENDICES Iridium Pilot Land Station Installation Guide 35...
Page 55: ...5 APPENDICES 50 Iridium Pilot Land Station Installation Guide...
Page 69: ...5 APPENDICES 64 Iridium Pilot Land Station Installation Guide...