5. Operation

Control board

Press the Menu until one of the following had been displayed:

Menu

Menu 1

Menu 2

Value

Description

DMX

Addr.

1-512

DMX512 address

Channel

CH01

0-255

Dimmer

CH02

0-255

DimmerFine, 5% brightness increased 

based on 01CH

CH03

0-255

Strobe

Manual

Dim

0-255

Dimmer

D_F

0-255

DimmerFine

STO

0-255

Strobe

Reset

YES/NO

Recover to manufactory default

Temperature

C.000

0-255

Current temperature

T.080

Protecting temperature

Use ‘Up’ and ‘Down’ button to select your desired operation, press ‘Enter’ to set all function

Notes:

» When there’s a flickering ‘!’ sign appeared, means no signal input for the fixture. 

» No operation within 30seconds, LCD display will enter into Screen protection mode automatic.

» When the current temperature is higher than the protecting setting temperature, 30% of power consumption will be 

deducted slowly; Power consumption will be coming to normal when the temperature gets to normal.   

 

 

6

Summary of Contents for 113777

Page 1: ...iridium Stage Profile Product Code 113777 ...

Page 2: ...2 ...

Page 3: ...fety instructions Proper Use Care 3 Description Products features Overview 4 Installation Overhead rigging DMX512 connection Power Input 5 Operation Control board DMX modes 6 Replacing the fuse 7 Focus 8 Technical specification 3 ...

Page 4: ...ation regulations applicable at your location Make sure that the cables and plugs are not subject to tension or torsional forces and do not bend the cables Protect all cables and insulation against possible damages Output lines should be laid separately and spaced apart from other lines The power supply cables and the lamp feeders must not cross each other Do not allow the product to come into con...

Page 5: ...t be constructed in a way that no part of the installation can fall down if the main attachment fails The operator has to make sure that safety relating and machine technical installations are approved by an expert and before taking into operation for the first time and after changes Please note for overhead rigging in public or industrial areas a series of safety instructions have to be followed ...

Page 6: ...ry default Temperature C 000 0 255 Current temperature T 080 Protecting temperature Use Up and Down button to select your desired operation press Enter to set all function Notes When there s a flickering sign appeared means no signal input for the fixture No operation within 30seconds LCD display will enter into Screen protection mode automatic When the current temperature is higher than the prote...

Page 7: ...ce the fuse by a fuse of same type and rating Before replacing the fuse unplug mains lead Procedure Step1 Unscrew the fuse holder on the rear panel with a fitting screwdriver from the housing anticlockwise Step 2 Remove the old fuse from the fuse holder Step 3 Install the new fuse in the fuse holder Step 4 Replace the fuse holder in the housing and fix it 7 Focus The objective lens cylinder is usu...

Page 8: ...imaging glass optical lens Color temperature 3200K CRI 90 Beam Angle 19 Dimming Range 16bit smooth dimming 0 100 DMX Channel 1CH 2CH 3CH Optional Control system STM32 control chip DMX512 signal Display Screen 4 Button LCD Screen IP Rating IP20 Min Distance to Illuminated object 1M Ambient Temp 15 C 35 C Product size 538x270x427mm Weight 10kgs Packing 1pc per carton Packing size 665x330x360mm 8 ...

Page 9: ......

Page 10: ...IMPORTER B K LUMITEC ZI 2 Rue Alfred Kastler 67850 Herrlisheim France www bklumitec com ...

Reviews: