5. Operation
Control board
Press the Menu until one of the following had been displayed:
Menu
Menu 1
Menu 2
Value
Description
DMX
Addr.
1-512
DMX512 address
Channel
CH01
0-255
Dimmer
CH02
0-255
DimmerFine, 5% brightness increased
based on 01CH
CH03
0-255
Strobe
Manual
Dim
0-255
Dimmer
D_F
0-255
DimmerFine
STO
0-255
Strobe
Reset
YES/NO
Recover to manufactory default
Temperature
C.000
0-255
Current temperature
T.080
Protecting temperature
Use ‘Up’ and ‘Down’ button to select your desired operation, press ‘Enter’ to set all function
Notes:
» When there’s a flickering ‘!’ sign appeared, means no signal input for the fixture.
» No operation within 30seconds, LCD display will enter into Screen protection mode automatic.
» When the current temperature is higher than the protecting setting temperature, 30% of power consumption will be
deducted slowly; Power consumption will be coming to normal when the temperature gets to normal.