background image

3. Description

 

- Made by fire-resistant Nylon material and Aluminum which makes the lamp more lighter

- Good performance of cooling system with the quiet fan

- DMX controlled operation, possible work with any commercial DMX512 controller

- Rail-type hanging bracket, bracket position can be adjusted

- Different dimmer curves and dimmer speed adjustable

- Flicker free projection 

- Rotatable barn doors, color filter optional

- Ready for connection with power cord with safety-plug

4. Installation

This device can be mounted in many orientations provided each individual device is secured by the use of correct 

mounting bracket. 

Overhead rigging

The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for 1hour 

without any harming deformation. The installation must always be secured with a secondary safety attachment. This 

secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main 

attachment fails. The operator has to make sure that safety-relating and machine-technical installations are approved 

by an expert and before taking into operation for the first time and after changes .

 

Please note: for overhead rigging in public or industrial areas, a series of safety instructions have to be followed that 

this manual can only give in part. 

DMX512 connection

If you are using controllers with this occupation, you can connect the DMX output of the controller directly with the DMX 

input of the first fixture in the DMX chain. 

Building a serial DMX chain: Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next 

fixture. Always connect one output with the input of the next fixture until all fixtures are connected.

For better signal receival, a signal amplifier suggest to be used for each 20 fixtures.

Power input

This device has an auto-switching power supply work with input voltage range of 100-230V AC, 50/60Hz. Link up to the 

maximum 8A, Do not exceed this. 

5

Summary of Contents for 113777

Page 1: ...iridium Stage Profile Product Code 113777 ...

Page 2: ...2 ...

Page 3: ...fety instructions Proper Use Care 3 Description Products features Overview 4 Installation Overhead rigging DMX512 connection Power Input 5 Operation Control board DMX modes 6 Replacing the fuse 7 Focus 8 Technical specification 3 ...

Page 4: ...ation regulations applicable at your location Make sure that the cables and plugs are not subject to tension or torsional forces and do not bend the cables Protect all cables and insulation against possible damages Output lines should be laid separately and spaced apart from other lines The power supply cables and the lamp feeders must not cross each other Do not allow the product to come into con...

Page 5: ...t be constructed in a way that no part of the installation can fall down if the main attachment fails The operator has to make sure that safety relating and machine technical installations are approved by an expert and before taking into operation for the first time and after changes Please note for overhead rigging in public or industrial areas a series of safety instructions have to be followed ...

Page 6: ...ry default Temperature C 000 0 255 Current temperature T 080 Protecting temperature Use Up and Down button to select your desired operation press Enter to set all function Notes When there s a flickering sign appeared means no signal input for the fixture No operation within 30seconds LCD display will enter into Screen protection mode automatic When the current temperature is higher than the prote...

Page 7: ...ce the fuse by a fuse of same type and rating Before replacing the fuse unplug mains lead Procedure Step1 Unscrew the fuse holder on the rear panel with a fitting screwdriver from the housing anticlockwise Step 2 Remove the old fuse from the fuse holder Step 3 Install the new fuse in the fuse holder Step 4 Replace the fuse holder in the housing and fix it 7 Focus The objective lens cylinder is usu...

Page 8: ...imaging glass optical lens Color temperature 3200K CRI 90 Beam Angle 19 Dimming Range 16bit smooth dimming 0 100 DMX Channel 1CH 2CH 3CH Optional Control system STM32 control chip DMX512 signal Display Screen 4 Button LCD Screen IP Rating IP20 Min Distance to Illuminated object 1M Ambient Temp 15 C 35 C Product size 538x270x427mm Weight 10kgs Packing 1pc per carton Packing size 665x330x360mm 8 ...

Page 9: ......

Page 10: ...IMPORTER B K LUMITEC ZI 2 Rue Alfred Kastler 67850 Herrlisheim France www bklumitec com ...

Reviews: