Author: RRi
Page - 11 -
Version 1.3
Date: 10-2019
BLANKOM-HDM-4230_User_Manual_ENv1.3.docx
MPEG2/4 HD-SDI to QAM and IP Encoder User Manual
Connect the PC (Personal Computer) and the device with network cable directly (Check usage of
crosslink cable eventually or network interface should support MDI/MDX), or using a at least
Fast Ethernet 100BaseT switch and use a "ping" command to confirm they are on the same
network segment.
I.e. the PC IP address is 192.168.99.252, we then change the device IP to 192.168.02.xxx (xxx
can be 1 to 254 except 252 to avoid an IP conflict) according to the EMU IP.
Use your web browser like Firefox, to connect the device with your PC/Laptop by entering the
URL of the Encoder & Modulator’s IP address in the browser’s address bar and press Enter:
A Popup will show the Login interface. Insert the Username and Password (Both default
Username and Password are “admin”) and then click OK to enter the device setting menu.
Note: We recommend using the newest version of the browser Firefox.
3.1.1 Network configuration basics:
NMS and DATA port should not use the same subnet at all. It checks whether these settings are
correct and separated - otherwise it refuses.
The problem is that both RJ45 are not secured against a loop. The solution is that you need to
separate the NMS from the Streaming network as described before. Network Menu:
The change will immediately take effect after confirming it with SET button. So you need to
login with the new IP address here as example changed to 192.168.0.137: