Menu item ‘Overview’ (Menu -> Overview)
After successful login, the
Overview
menu will be displayed. This menu is used to assign the outputs to the
corresponding inputs. This can be done by clicking in the respective column (e.g. system A HH) and row (e.g.
OUT 8). After that, a green tick will be displayed in this field. Furthermore, information about the DC status, RF
status, the redundancy behaviour and the run time of the device is given in this menu. The
Refresh
button updates
the displayed status. At the bottom of the menu, the button
Save
is located. After pressing this button, the selected
values will be set.
Location
In this menu item the location of the device will be displayed. The Location can be edited in the menu item
Network Settings
.
OP Hours
This menu item shows the operating time of the device.
Redundancy Status
This menu item provides information about the current status of the power supply redundancy. A green tick
shows that the redundancy is operating in an error-free state. If a red cross is displayed, no redundancy is
active.
RF Status
The RF status is used to monitor the SAT IF input signals. A green tick indicates if a signal is applied
to the corresponding SAT input connector. If a red cross is displayed, no or a too low input signal is present at
the assigned connector (<60 dBμV sum signal).