Iradion Infinity 1510 Operator'S Manual Download Page 15

15 

 

 

Caution 

 

This unit is provided with a 1-meter length of cable for DC power. If the wire is extended 
in length, #10 wire must be used.  Do not add more than 1 meter additional wire unless 
it is heavier than #10.  Power supply regulation should be greater than ±2% and ripple 
no greater than 400 mV.  No damage can occur to the laser if the DC voltage is in the 
range of 0 to 50 Volts; however, the laser will only operate at the specified voltage. 
Check your power supply before attachment and adjust it to the

 specified voltage

. The 

software will not allow more than ≈± 2 Volts variation including line drops at high current 
settings. 

If output becomes intermittent and the fault light flashes on and off, the 

voltage drop on the power cable may be too large or the power supply may be 
bad.  If the fault light lights up on power up, check the power supply voltage 
setting.

 

 

 

Nominal Operating Voltages 

 

Model Number: 

155 

155 9.3 

156 

156 9.3 

158 

1510 

1512 

DC Voltage: 

36V 

45V 

40V 

50V 

45V 

50V 

50V 

 

 

“F” Type Lasers 

 

Current  production  lasers  are  marked,  for  example,  as  156F.  These  lasers  are  designed  to 
control fan operation internally based on the operating temperature. The fan will start operating 
at 32°C or higher and will stop at 30°C or lower.  This fan function is enabled via commands sent 
over the RS 232 lines.  If the fans do not start when power is applied,  this means that the fan 
function is disabled.  If fans do not start with power up, this does not indicate fan malfunction!  
Factory fresh lasers are always shipped with the fan function disabled.  See the Iradion LCC 
Comm Protocol_v1.5 for information on communicating with the laser control card. 

 

“W” Type Lasers 

 
Water cooled lasers require water connections before operation. 

See “Other Connection Details” 

below.  Water cooled lasers cannot detect water flow.  If the laser is operated without water flow, 
a fault will occur  due to overheating after  several minutes  (depending on the operating duty).  
Damage will not occur. 
 
 
 
 
 
 
 
 
 

Summary of Contents for Infinity 1510

Page 1: ...92 3005 MADEinUSA OPERATOR S MANUAL Infinity Series CO2 Laser Models 155 through 1512 www Iradion com...

Page 2: ...wer Cable All Lasers 12 Connector RJ 45 All Lasers 12 Connector HD 15 Lasers Shipped AFTER January 1 2016 13 Connector HD 15 Lasers Shipped BEFORE January 1 2016 14 Nominal Operating Voltages 15 F Typ...

Page 3: ...aser equipment Terms Certain terms are used throughout the manual or on the equipment labels Please familiarize yourself with their definitions and significance Danger Imminent hazards which if not av...

Page 4: ...tions from metallic surfaces Enclose the beam path whenever possible Exposure to direct or diffuse CO2 laser radiation can seriously burn human or animal tissue which may cause permanent damage This p...

Page 5: ...als being processed should be thoroughly evaluated and the adequacy of provisions for fume extraction filtering and venting should be carefully considered Review the following reference for further in...

Page 6: ...6 Label Locations...

Page 7: ...typical for this product family when incorporated for intended use A risk of injury when lifting or moving the unit B risk of exposure to hazardous laser energy through unauthorized removal of access...

Page 8: ...Name Infinity Model Number 15XX Conforms to the following Directive s and Standard s Applicable Standard s IEC 60825 1 3rd Ed 2014 Safety of Laser Products EN 55011 2009 A1 2010 Group 2 Class A ISM e...

Page 9: ...t Name Infinity Model Number 15XX To comply with RoHS II all CE marked products require a Declaration of Conformity DoC and that a technical file be made available upon request For finished EEE where...

Page 10: ...of these safety features are available and it is expected that the user will apply them and fully comply with all CDRH requirements Available Safety Features The following safety features are availabl...

Page 11: ...ges under the cover that will cause serious RF burns to the skin if touched Caution The lasers are waveguide lasers with a slab unstable optical resonator The resulting elliptical beam is corrected by...

Page 12: ...wire to power supply Ground Red Power VDC positive connection 10 gauge wire to power supply Connector RJ 45 All Lasers Designation Pin Description Comment RJ 45 1 Modulation High in TTL relative to G...

Page 13: ...ch in Ground this line through key switch to arm laser Page 10 HD 15 Pin 7 Fault LED drive pin Signal to drive an LED directly with grounded cathode 5V 33mA 150 series resistor HD 15 Pin 8 Forward Mon...

Page 14: ...6 Key Switch in Ground this line through key switch to arm laser Page 10 HD 15 Pin 7 Fault LED drive pin Signal to drive an LED directly with grounded cathode 12V at 25mA 470 series resistor HD 15 Pi...

Page 15: ...g Voltages Model Number 155 155 9 3 156 156 9 3 158 1510 1512 DC Voltage 36V 45V 40V 50V 45V 50V 50V F Type Lasers Current production lasers are marked for example as 156F These lasers are designed to...

Page 16: ...6 second delay before the green READY light lights up This switch must be toggled to arm the system after power up NOTE This function depends on the software version and programing OEM lasers are ship...

Page 17: ...dion LCC Comm Protocol_v1 5 document The laser command line modulation high requires a 1 to 3 Sec pulse repeated at 200 Sec intervals when there is no output commanded There is an adjustable pulse str...

Page 18: ...4 high and the RJ 45 pins 1 high and 6 low are designed to allow either floating or grounded input modes Both the High and Low pins should be used in either case A software setting made through the R...

Page 19: ...be detected by viewing the LED indicators on the rear of the laser The signals monitored with LEDs are LASER READY Lights up when the laser controller is ready for operation OVERTEMP Lights up when th...

Page 20: ...cooling connections The rear plate of these lasers is pictured below Cooling Specifications Flow Rate 3 78 7 56 liters minute Water Temp Non Condensing 18 C to 24 C Inlet Pressure 413kPa Hardness 250...

Page 21: ...control corrosion and algae as recommended by the manufacturer of the chiller Use high quality water such as distilled or deionized water to avoid scale buildup Keep the concentration of water at abov...

Page 22: ...ions indicate The chart below shows the dew point at various air temperatures and relative humidity To determine the dew point temperature measure the air temperature and relative humidity Draw a hori...

Page 23: ...functions are Get Status Get Options Get Laser Serial Number Set Auto Fan Enable if this hardware option is available Set Auto Fan Disable if this hardware option is available Set Mod Low Grounded Set...

Page 24: ...24 Mechanical Outline...

Page 25: ...m 10 6 m 10 2 m 10 6 m Rise Time S 75 75 75 75 75 Pulse Duration S 10 200 10 200 10 200 10 200 10 200 Duty Cycle 0 100 0 100 0 100 0 100 0 100 Power Stability Fan Cooled from cold start 6 6 6 6 6 Pow...

Page 26: ...nce mR full angle 5 2 5 2 Wavelength m 9 3 m 9 3 m Rise Time S 75 75 Pulse Duration S 10 200 10 200 Duty Cycle 0 100 0 100 Power Stability Fan Cooled from cold start 7 7 Power Stability Water Cooled f...

Page 27: ...ical damage to lens RFPA malfunction Fault light is lit The laser is too hot The DC voltage is outside the proper range Indicator Lights Details The following chart is provided for clarity RED FAULT o...

Reviews: